Page 4 - Linde - VT Modular, Modular system for LSC manifold valve plates
P. 4

Model Code Build.








         VT1     0123      01       XX      0ABC      035     0ABC      035      EH       23      ABCD    00XXC0

         1,2,3     4        5        6,7      8        9        10       11       12       13       14      15,16



          1,2,3    Product                    9  Left Tank Port Check Pressure   14  Valve Type, Position 0
        VT1 - LSC Hydraulic Main Control Valve   0 - No tank check              A - Asymmetrical Metering Spool, A and B
                                            3 - 3 bar crack pressure (standard)   blocked in neutral
          4  Bank Configuration             5 - 5 bar crack pressure (standard)   B - Symmetrical Metering Spool, A and B
        0 - Base block with P port only                                         blocked in neutral
        1 - Base block with P port plus 1    10  Tank Check - Right Tank Port   C - Symmetrical Metering Spool, A and B
        expansion module                    0 - No tank check                   open to Tank in neutral
        2 - Base block with P port plus 2   A - Tank check with port facing down  D - Symmetrical Metering Spool with straight
        expansion modules                   (standard)                          tracking feature (25 size only)
        3 - Base block with P port plus 3   B - Tank check with port facing out
        expansion modules                   C - Tank check with port facing up    15,16    A Port Valve and Setting,
                                                                                Position 0
          5  Pressure Control Block          11  Right Tank Check Pressure      0,0 - No port relief or anti-cav check
        0 - No pressure control module      0 - No tank check                   (plugged cavity)
        1 - With pressure control module    3 - 3 bar crack pressure (standard)  X,X - Port relief setting (in ten bar
        (standard)                          5 - 5 bar crack pressure (standard)  increments) (90 bar to 400 bar)
                                                                                (380 bar standard)
          6,7  Pressure Control Setting      12  Valve Actuation Type, Position 0  C,0 - Anti-cav Check (2 bar cracking pres-
        XX - Load Sense relief in 10 bar    E - 24 volt proportional, Integral Deutsch   sure)
        increments (160 to 370 bar)         male connector (standard)
        (350 bar standard)                  H - Hydraulically piloted, 6-19 bar      17,18    B Port Valve and Setting,
                                            (standard)                          Position 0
          8  Tank Check - Left Tank Port                                        0,0 - No port relief or anti-cav check
        0 - No tank check                    13  Valve Size, Position 0         (plugged cavity)
        A - Tank check with port            2 - 25 size valve                   X,X - Port relief setting (in ten bar
        facing down (standard)              3 - 30 size valve                   increments) (90 bar to 400 bar)
        B - Tank check with port facing out                                     (380 bar standard)
        C - Tank check with port facing up                                      C,0 - Anti-cav Check (2 bar cracking
                                                                                pressure)
                                                                                         Note: If position 4 = 0,
                                                                                     omit position codes 19 through 60























    4
   1   2   3   4   5   6   7   8   9