Page 4 - Linde - VT Modular, Modular system for LSC manifold valve plates
P. 4
Model Code Build.
VT1 0123 01 XX 0ABC 035 0ABC 035 EH 23 ABCD 00XXC0
1,2,3 4 5 6,7 8 9 10 11 12 13 14 15,16
1,2,3 Product 9 Left Tank Port Check Pressure 14 Valve Type, Position 0
VT1 - LSC Hydraulic Main Control Valve 0 - No tank check A - Asymmetrical Metering Spool, A and B
3 - 3 bar crack pressure (standard) blocked in neutral
4 Bank Configuration 5 - 5 bar crack pressure (standard) B - Symmetrical Metering Spool, A and B
0 - Base block with P port only blocked in neutral
1 - Base block with P port plus 1 10 Tank Check - Right Tank Port C - Symmetrical Metering Spool, A and B
expansion module 0 - No tank check open to Tank in neutral
2 - Base block with P port plus 2 A - Tank check with port facing down D - Symmetrical Metering Spool with straight
expansion modules (standard) tracking feature (25 size only)
3 - Base block with P port plus 3 B - Tank check with port facing out
expansion modules C - Tank check with port facing up 15,16 A Port Valve and Setting,
Position 0
5 Pressure Control Block 11 Right Tank Check Pressure 0,0 - No port relief or anti-cav check
0 - No pressure control module 0 - No tank check (plugged cavity)
1 - With pressure control module 3 - 3 bar crack pressure (standard) X,X - Port relief setting (in ten bar
(standard) 5 - 5 bar crack pressure (standard) increments) (90 bar to 400 bar)
(380 bar standard)
6,7 Pressure Control Setting 12 Valve Actuation Type, Position 0 C,0 - Anti-cav Check (2 bar cracking pres-
XX - Load Sense relief in 10 bar E - 24 volt proportional, Integral Deutsch sure)
increments (160 to 370 bar) male connector (standard)
(350 bar standard) H - Hydraulically piloted, 6-19 bar 17,18 B Port Valve and Setting,
(standard) Position 0
8 Tank Check - Left Tank Port 0,0 - No port relief or anti-cav check
0 - No tank check 13 Valve Size, Position 0 (plugged cavity)
A - Tank check with port 2 - 25 size valve X,X - Port relief setting (in ten bar
facing down (standard) 3 - 30 size valve increments) (90 bar to 400 bar)
B - Tank check with port facing out (380 bar standard)
C - Tank check with port facing up C,0 - Anti-cav Check (2 bar cracking
pressure)
Note: If position 4 = 0,
omit position codes 19 through 60
4