Page 5 - Linde - VT Modular, Modular system for LSC manifold valve plates
P. 5
Model Code Build.
00XXC0 SPD EH 023 0ABCD 00XXC0 00XXC0 023 0ABCD 00XXC0 00XXC0
17,18 19 20 21 22 23,24 25,26 27 28 29,30 31,32
19 Expansion Block Type, Position 1 23,24 A Port Valve and Setting, 28 Valve Type, Position 1, Bottom
S - Single Station, no bottom porting Position 1 Top 0 - No Valve (Blanking Plate)
P - Single Station, P port on bottom 0,0 - No port relief or anti-cav check (plug- A - Asymmetrical Metering Spool, A and B
D - Double Station, porting for second valve ged cavity) blocked in neutral
on bottom X,X - Port relief setting (in ten bar incre- B - Symmetrical Metering Spool, A and B
Note: If additional expansion blocks are required, ments) (90 bar to 400 bar) (380 bar stan- blocked in neutral
repeat positions 19 through 32. A total of three dard) C - Symmetrical Metering Spool, A and B
expansion blocks may be used. open to Tank in neutral
C,0 - Anti-cav Check (2 bar cracking pres- D - Symmetrical Metering Spool with straight
20 Valve Actuation Type, Position 1 sure) tracking feature (25 size only)
E - 24 volt proportional, Integral Deutsch 25,26 B Port Valve and Setting,
male connector (standard) Position 1 Top 29,30 A Port Valve and Setting,
H - Hydraulically piloted, 6-19 bar (standard) Position 1 Bottom
0,0 - No port relief or anti-cav check (plug- 0 - No port relief or anti-cav check (plugged
ged cavity)
21 Valve Size, Position 1, Top cavity)
X,X - Port relief setting (in ten bar incre-
0 - No Valve (Blanking Plate) X,X - Port relief setting (in ten bar incre-
ments) (90 bar to 400 bar) (380 bar stan-
2 - 25 size valve dard) ments) (90 bar to 400 bar) (380 bar stan-
3 - 30 size valve C,0 - Anti-cav Check (2 bar cracking dard)
pressure) C,0 - Anti-cav Check (2 bar cracking pres-
22 Valve Type, Position 1, Top Note: If position 19 = S or P, sure)
0 - No Valve (Blanking Plate) omit position codes 27 through 32
31,32 B Port Valve and Setting,
A - Asymmetrical Metering Spool, A and B Position 1 Bottom
blocked in neutral 27 Valve Size, Position 1, Bottom 0,0 - No port relief or anti-cav check (plug-
0 - No Valve (Blanking Plate)
B - Symmetrical Metering Spool, A and B ged cavity)
blocked in neutral 2 - 25 size valve
3 - 30 size valve X,X - Port relief setting (in ten bar incre-
C - Symmetrical Metering Spool, A and B ments) (90 bar to 400 bar) (380 bar stan-
open to Tank in neutral dard)
D - Symmetrical Metering Spool with straight C,0 - Anti-cav Check (2 bar cracking pres-
tracking feature (25 size only) sure)
Note: If position 4 = 1,
omit position codes 33 through 60
5