Page 101 - Parker - Vacuum products
P. 101

Catalog 0802-E                                      Vacuum Generators
            System Logic                                        CEK Emergency Stop Vacuum Generators

            CEK - System logic


                                                          Idle



                                                  Vacuum ON Command
                                                   from System Controls


                                                                                                                    B
                                                     Vacuum Begins
                                                                           Vacuum
                                                                            Mode
                                                                          Continues

                                            Yes        Maximum         No                                            Generator   Selection
                                                     Setting Reached
                                                         (H-1)

                           Air Conservation Begins                                                                   MCA, CV,   CV-CK
                               Output 1 On                         Command                   Yes
                           Check Valve Maintains                Vac “Off” Blow “On”
                               Vacuum Level                                                                          CHF
                                                                        No

                                                                                          Emergency Stop             MC22
                                                       Yes       Is Vacuum Level             System
                                                                  Maintained?                 To Idle
                        Vacuum Level                                                                                 MC72
                        Restored To                                     No
                      Maximum Setting                                                       Emergency Stop
                           (H-1)                                 Sensor Detects                System
                                                                Hysteresis Level          Vacuum Maintained          CEK
                                                                   Reached
                                                                                                                     CVXCEK
                                                                (H-1) minus (h-1)


                                                                                                                     MPS-23
            CEK - Emergency Stop
            Operating System (EOS)
            The Emergency Stop Operating System is designed to maintain   The chart below illustrates the state of operation in different   MVS-201
            the last state of operation when an emergency stop or power   modes.
            failure occurs.
                                                                                                                     Generator
            Modes               Vacuum On              Vacuum Off           Blow-Off             EOS                   Accessories
                                Air-Economizing between                     Blow-Off On
            Normal Conditions                          Idle                                      EOS Off
                                18-16 inHg                                  Blow-Off Idle
                                Vacuum On                                   Blow-Off
                                                                            On or Idle                               Glossary
            Emergency Stop,
            Power Failure                              Idle                                      EOS On

                                Vacuum On                                   Idle
                                Vacuum On
            Restore Power       Air-Economizing        Idle                 Idle                 EOS Off
                                Function Resumes

                                                            B31                        Parker Hannifin Corporation
                                                                                       Pneumatic Division
                                                                                       Richland, Michigan
                                                                                       www.parker.com/pneumatics
   96   97   98   99   100   101   102   103   104   105   106