Page 105 - Parker - Vacuum products
P. 105

Catalog 0802-E                   (Revised 02-01-12)  Vacuum Generators
            System Logic                                       CVXCEK Emergency Stop Vacuum Generators



                                                             Idle


                                     VAC "ON"          Command VAC "ON"
                             Robot             Sensor Output 1 N.O. Preset, P-1 = 18 inHg
                           Controller  Part Presence Sensor Output 2 N.C. Preset, n-3 = 10 inHg
                                                          (P-2) > n-3



                                                        Vacuum Begins                                               B
                                                                               Vacuum
                                                                                 Mode
                                                                              Continues

                                       YES                                       NO
                                                      Max. Setting Reached?
                                                            (P-1)                                                    Generator   Selection


                             Air Conservation Begins               PLC Command                                       MCA, CV,   CV-CK
                               Output 1 "OFF"                                       YES
                             Check Valve Maintains                  Vacuum "OFF"
                                                                    Blow-Off "ON"
                                Vacuum Level
                                                                                                                     CHF
                                                                         NO
                                                                                         Emergency
                                                                                            Stop
                                                       YES         Is Vacuum Level         System                    MC22
                                                                    Maintained?            to Idle
                                                                       (P-2)
                        Vacuum Level                                     NO
                        Restored to                                                         Emergency Stop           MC72
                        Max.Setting        Output 1 to Activate Vacuum  Sensor Detects       System Vacuum
                                                                 Bottom Level Reached         Maintained
                                                                                                                     CEK



            The Emergency Stop Operating System is designed to maintain                                              CVXCEK
            the last state of operation when an emergency stop or power
            failure occurs.
            The chart below illustrates the state of operation in different                                          MPS-23
            modes.
                                                                                                                     MVS-201

            Modes                       Vacuum on                 Vacuum off              Blow-off
            Normal                      Air economizing                                   Blow-off on
            Conditions                  18 to 15.5 inHg           Idle                    Blow-off idle
            Emergency stop event                                                                                     Generator   Accessories
                                                                                          On    Idle
            Input power on              Air economizing
            Output power off            18 to 15.5 inHg           Idle
                                                                                          Idle    Idle
                                        Vacuum on                                         On    Idle
            Input power off                                       Idle                                               Glossary
            Output power on
                                        Max. vacuum on                                    Idle    Idle
                                        Vacuum on                                         On    Idle
            Input power off                                       Idle
            Output power off
                                        Max. vacuum on                                    Idle    Idle
            Restore power               Vacuum on
            Input power on              Air economizing           Idle                    Idle
            Output power on             18 to 15.5 inHg

                                                            B35                        Parker Hannifin Corporation
                                                                                       Pneumatic Division
                                                                                       Richland, Michigan
                                                                                       www.parker.com/pneumatics
   100   101   102   103   104   105   106   107   108   109   110