10    Pluggable Modules on Terminal Blocks - Surge Suppression Devices



  478
                                            Single stage suppression for 3-wire control,   Single stage suppression for 3-wire control,
                                            signal or power circuits           signal or power circuits
                                            No interruption of current flow when   No interruption of current flow when
                                            changing module with fault indication   changing module with fault indication
                                            110 V / 120 V AC                   230 V AC
                                            Module width 15 mm / 0.591 in      Module width 15 mm / 0.591 in


        Note:
        For isolation measurements the ground (earth) contact at
        the transient suppression module must be disconnected.

        WSB marker card
        • Marking F; Item No.: 209-791
        • Marking 1 ... 10; Item No.: 209-702
        • Marking Lin, N, PE Lout, N, PE, Lin, N, PE;
          Item No.: 249-655
        5 cards, each containing 10 strips with 10 markers




                                           L IN                          L OUT  L IN                        L OUT

                                                    ϑ  ϑ                               ϑ  ϑ

                                           N                             N     N                            N
                                           PE                            PE    PE                           PE
        Description                                      Item No.        Pack.              Item No.        Pack.
                                            V BN
                                                                         Unit  V BN                         Unit
        Surge suppression module            230 V AC     286-838         1     115  V  AC   286-838/115-000  1










        Technical Data                             Accessories see pages 99 … 100     Accessories see pages 99 … 100
                                                         230 V AC                           115 V AC
        Nominal operating voltage V BN
        Operating voltage                                300 V AC                           150 V AC
        Nominal current                                    10 A                               10 A
        Nominal discharge current between L/N and PE       1 kA                               1 kA
        Nominal discharge current between L and N          1 kA                               1 kA
        Max. surge current between L/N and PE             2.5 kA                             2.5 kA
        Max. surge current between L and N                2.5 kA                             2.5 kA
        Protection level between L/N and PE                1 kV                               800 V
        Protection level between L and N                  800 V                               400 V
        Response time between L/N and PE                   1 μs                               1 μs
        Response time between L and N                      25 ns                              25 ns
        Nominal voltage to EN 60664-1                  250 V / 4 kV / 2                   250 V / 4 kV / 2
        Ambient operating temperature                  -25 °C ... +85 °C                  -25 °C ... +85 °C
        Dimensions (mm) L x H x W incl. terminal block  17 x 82.5 x 73                     17 x 82.5 x 73