1
89
Relay with 1 make contact for higher DC loads
1
Module width 15 mm / 0.591 in
11
A1 11
+
A2
–
A2 14
–
Description Item No. Pack.
Unit
V N
I N
Switching relay module 24 V DC 20 mA 286-376 1
8
Technical Data Accessories see pages 99 … 100
Contact material AgNi 0.15
Max. switching voltage 250 V AC
Max. make current (resistive) 4 s 14A
Recommended minimum load > 12 V / 10 mA AC/DC
Max. continuous current 5 A
Max. switching power (resistive) 2000 VA
Pull-in/drop-out/bounce time typ. 9ms / 3ms / ms
Dielectric strength contact-coil (AC, 1 min) 4 kV
Dielectric strength open contact 2 kV
Nominal voltage acc. to VDE 0110 Part 1/4.97, 250 V / 4 kV / 2
IEC 60664-1
6
Mechanical life 20 x 10 switching operations
5
Mechanical life at max. load (resistance) 3 x 10 switching operations
Ambient operating temperature -25 °C ... +40 °C
Standards/specifications EN 60664-1
Accessories Item No. Pack.
Unit
Terminal block for pluggable modules, with 2-
conductor terminal blocks, orange separator ➊ 17 mm / 0.669 in wide 280-619 1
with 4-conductor terminal blocks, orange separator ➋ 17 mm / 0.669 in wide 280-609 1
with 4-conductor terminal blocks, marker plate ➋ 20 mm / 0.787 in wide 280-763 1
wire range 0.08 mm² ... 2.5 mm² / AWG 28 ... 14;
stripped length 8 ... 9 mm / 0.33 in