ORDERING CODE - T6C SERIES INDUSTRIAL APPLICATION

            Model No.                    T6C -   022   -  1 R 00 - B    1

            Series                                                              Modification
            Cam ring                                                            Seal class
            (Delivery at 0 PSI & 1200 r.p.m.)                                   1 = S1 (for mineral oil)
            003 =   3.42 GPM  017 = 18.48 GPM                                   4 = S4 (for resistant fluids)
            005 =   5.45 GPM  020 = 20.23 GPM                                   5 = S5 (for mineral oil and fire
            006 =   6.76 GPM  022 = 22.28 GPM                                                resistant fluids)
            008 =   8.36 GPM  025 = 25.14 GPM
            010 = 10.81 GPM  028 = 27.90 GPM                                    Design letter
            012 = 11.76 GPM  031 = 31.70 GPM                                    Porting combination
            014 = 14.58 GPM                                                     00 = standard
            Type of shaft                                                       Direct. of rotation (view on shaft end)
            1 = keyed (SAE B)                                                   R = clockwise
            2 = keyed (no SAE)                                                  L = counter-clockwise
            3 = splined (SAE B)
            4 = splined (SAE BB)
                                                                                P = Pressure port
                                                                                S = Suction port


                       INTERNAL LEAKAGE (TYPICAL)                         NOISE LEVEL (TYPICAL)
                                                                                  T6C - 022



              Internal leakage qVs [GPM]                       Lp. Noise level [db(A)] 1m ISO 4412














                              Pressure p [PSI]                                 Pressure p [PSI]
            Do not operate the pump more than 5 seconds at any speed or
            viscosity, if internal leakage is more than 50% of theoretical flow.




                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD







              Power loss Ps [HP]                               Load F [Lbs]












                              Pressure p [PSI]                                  Speed n [RPM]

                                                               Maximum permissible axial load Fa = 180 Lbs





                                                                                         Parker Hannifin
                         10                         Back To The Table Of Content         Denison Vane Pump Division
                                                                                         Vierzon - France