Page 13 - Parker - Vane pumps single, double, triple T6 industrial application
P. 13

ORDERING CODE - T6D SERIES INDUSTRIAL APPLICATION

            Model No.                    T6D -   045   -  1 R 00 - B    1

            Series                                                              Modification
            Cam ring                                                            Seal class
            (Delivery at 0 PSI & 1200 r.p.m.)                                   1 = S1 (for mineral oil)
            014 = 15.09 GPM  035 = 35.19 GPM                                    4 = S4 (for resistant fluids)
            017 = 18.45 GPM  038 = 38.14 GPM                                    5 = S5 (for mineral oil and fire
            020 = 20.93 GPM  042 = 43.12 GPM                                                 resistant fluids)
            024 = 25.20 GPM  045 = 46.19 GPM
            028 = 28.44 GPM  050 = 50.09 GPM                                    Design letter
            031 = 31.16 GPM                                                     Porting combination
            Type of shaft                                                       00 = standard
            1 = keyed (SAE C)                                                   Direct. of rotation (view on shaft end)
            2 = keyed (no SAE)                                                  R = clockwise
            3 = splined (SAE C)                                                 L = counter-clockwise
            4 = splined (no SAE)

                                                                                P = Pressure port
                                                                                S = Suction port


                       INTERNAL LEAKAGE (TYPICAL)                         NOISE LEVEL (TYPICAL)
                                                                                  T6D - 038



              Internal leakage qVs [GPM]                       Lp. Noise level [db(A)] 1m ISO 4412














                              Pressure p [PSI]                                 Pressure p [PSI]







                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD







              Power loss Ps [HP]                              Load F [Lbs]












                              Pressure p [PSI]                                  Speed n [RPM]

                                                                Maximum permissible axial load Fa = 270 Lbs





                                                                                         Parker Hannifin
                         12                         Back To The Table Of Content         Denison Vane Pump Division
                                                                                         Vierzon - France
   8   9   10   11   12   13   14   15   16   17   18