Page 15 - Parker - Vane pumps single, double, triple T6 industrial application
P. 15

ORDERING CODE - T6E SERIES INDUSTRIAL APPLICATION

            Model No.                    T6E -   066   -  3 R 00 - A 1

            Series                                                              Modification
            Cam ring                                                            Seal class
            (Delivery at 0 PSI & 1200 r.p.m.)                                   1 = S1 (for mineral oil)
            042 = 41.94 GPM  062 = 62.36 GPM                                    4 = S4 (for resistant fluids)
            045 = 46.15 GPM  066 = 67.62 GPM                                    5 = S5 (for mineral oil and fire
            050 = 50.25 GPM  072 = 72.00 GPM                                                 resistant fluids)
            052 = 52.25 GPM
                                                                                Design letter
            Type of shaft
            1 = keyed (SAE CC)                                                  Porting combination
            2 = keyed (no SAE)                                                  00 = standard
            3 = splined (SAE C)                                                 Direct. of rotation (view on shaft end)
            4 = splined (SAE CC)                                                R = clockwise
                                                                                L = counter-clockwise


                                                                                P = Pressure port
                                                                                S = Suction port


                       INTERNAL LEAKAGE (TYPICAL)                         NOISE LEVEL (TYPICAL)
                                                                                  T6E - 050



              Internal leakage qVs [GPM]                       Lp. Noise level [db(A)] 1m ISO 4412














                              Pressure p [PSI]                                 Pressure p [PSI]







                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD







              Power loss Ps [HP]                              Load F [Lbs]












                              Pressure p [PSI]                                  Speed n [RPM]

                                                                Maximum permissible axial load Fa = 449 Lbs





                                                                                         Parker Hannifin
                         14                        Back To The Table Of Content          Denison Vane Pump Division
                                                                                         Vierzon - France
   10   11   12   13   14   15   16   17   18   19   20