Page 19 - Parker - Vane pumps single, double, triple T6 industrial application
P. 19
ORDERING CODE - T6DC SERIES INDUSTRIAL APPLICATION
Model No. T6DC W - 038 - 022 - 1 R 00 - B 1
Series Modification
P1 P2
Severe duty shaft Seal class
Cam ring for "P1" 1 = S1 (for mineral oil)
(Delivery at 0 PSI & 1200 r.p.m.) 4 = S4 (for resistant fluids)
014 = 15.09 GPM 035 = 35.19 GPM 5 = S5 (for mineral oil and fire
017 = 18.45 GPM 038 = 38.14 GPM resistant fluids)
020 = 20.93 GPM 042 = 43.12 GPM Design letter
024 = 25.20 GPM 045 = 46.19 GPM
028 = 28.44 GPM 050 = 50.09 GPM Porting combination (see page 30)
031 = 31.16 GPM 00 = standard
Cam ring for "P2" Direct. of rotation (view on shaft end)
(Delivery at 0 PSI & 1200 r.p.m.) R = clockwise
003 = 3.42 GPM 017 = 18.48 GPM L = counter-clockwise
005 = 5.45 GPM 020 = 20.23 GPM Severe duty shaft (T6DCW only) Type of shaft
006 = 6.76 GPM 022 = 22.28 GPM 5 = keyed (no SAE) 1 = keyed (SAE C)
008 = 8.36 GPM 025 = 25.14 GPM 2 = keyed (no SAE)
010 = 10.81 GPM 028 = 27.90 GPM 3 = splined (SAE C)
012 = 11.76 GPM 031 = 31.70 GPM 4 = splined (no SAE)
014 = 14.58 GPM
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)
T6DC - 038 - 022
Internal leakage qVs [GPM] Lp. Noise level [db(A)] 1m ISO 4412
Pressure p [PSI] Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or Double pump noise level is given with each section
viscosity, if internal leakage is more than 50% of theoretical flow. discharging at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
Power loss Ps [HP] Load F [Lbs]
Pressure p [PSI] Speed n [RPM]
Total hydrodynamic power loss is the sum of each section at its Maximum permissible axial load Fa = 270 Lbs
operating conditions.
Parker Hannifin
18 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France