ORDERING CODE - T6ED SERIES INDUSTRIAL APPLICATION
Model No. T6ED - 066 - 038 - 1 R 00 - B 1 -
Series P1 P2 Modification
Cam ring for "P1" Seal class
(Delivery at 0 PSI & 1200 r.p.m.) 1 = S1 (for mineral oil)
042 = 41.94 GPM 062 = 62.36 GPM 4 = S4 (for resistant fluids)
045 = 45.15 GPM 066 = 67.62 GPM 5 = S5 (for mineral oil and fire
050 = 50.25 GPM 072 = 72.00 GPM resistant fluids)
052 = 52.25 GPM
Design letter
Cam ring for "P2"
(Delivery at 0 PSI & 1200 r.p.m.) Porting combination (see page 30)
014 = 15.09 GPM 035 = 35.19 GPM 00 = standard
017 = 18.45 GPM 038 = 38.14 GPM Direct. of rotation (view on shaft end)
020 = 20.93 GPM 042 = 43.12 GPM R = clockwise
024 = 25.20 GPM 045 = 46.19 GPM L = counter-clockwise
028 = 28.44 GPM 050 = 50.09 GPM
031 = 31.16 GPM Type of shaft
1 = keyed (SAE CC)
2 = keyed (no SAE)
3 = splined (SAE C)
4 = splined (SAE CC)
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)
T6ED - 050 - 038
Internal leakage qVs [GPM] Lp. Noise level [db(A)] 1m ISO 4412
Pressure p [PSI] Pressure p [PSI]
Total leakage is the sum of each section loss at its operating Double pump noise level is given with each section
conditions. discharging at the pressure noted on the curve.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
Power loss Ps [HP] Load F [Lbs]
Pressure p [PSI] Speed n [RPM]
Total hydrodynamic power loss is the sum of each section at its Maximum permissible axial load Fa = 449 Lbs
operating conditions.