Page 21 - Parker - Vane pumps single, double, triple T6 industrial application
P. 21
ORDERING CODE - T6EC SERIES INDUSTRIAL APPLICATION
Model No. T6EC - 066 - 022 - 1 R 00 - B 1 -
Series P1 P2 Modification
Cam ring for "P1" Seal class
(Delivery at 0 PSI & 1200 r.p.m.) 1 = S1 (for mineral oil)
042 = 41.94 GPM 062 = 62.36 GPM 4 = S4 (for resistant fluids)
045 = 45.15 GPM 066 = 67.62 GPM 5 = S5 (for mineral oil and fire
050 = 50.25 GPM 072 = 72.00 GPM resistant fluids)
052 = 52.25 GPM
Design letter
Cam ring for "P2"
(Delivery at 0 PSI & 1200 r.p.m.) Porting combination (see page 30)
003 = 3.42 GPM 017 = 18.48 GPM 00 = standard
005 = 5.45 GPM 020 = 20.23 GPM Direct. of rotation (view on shaft end)
006 = 6.76 GPM 022 = 22.28 GPM R = clockwise
008 = 8.36 GPM 025 = 25.14 GPM L = counter-clockwise
010 = 10.81 GPM 028 = 27.90 GPM
012 = 11.76 GPM 031 = 31.70 GPM Type of shaft
014 = 14.58 GPM 1 = keyed (SAE CC)
2 = keyed (no SAE)
3 = splined (SAE C)
4 = splined (SAE CC)
INTERNAL LEAKAGE (TYPICAL) NOISE LEVEL (TYPICAL)
T6EC - 050 - 022
Internal leakage qVs [GPM] Lp. Noise level [db(A)] 1m ISO 4412
Pressure p [PSI] Pressure p [PSI]
Do not operate the pump more than 5 seconds at any speed or Double pump noise level is given with each section
viscosity, if internal leakage is more than 50% of theoretical flow. discharging at the pressure noted on the curve.
Total leakage is the sum of each section loss at its operating
conditions.
POWER LOSS HYDROMECHANICAL (TYPICAL) PERMISSIBLE RADIAL LOAD
Power loss Ps [HP] Load F [Lbs]
Pressure p [PSI] Speed n [RPM]
Total hydrodynamic power loss is the sum of each section at its Maximum permissible axial load Fa = 449 Lbs
operating conditions.
Parker Hannifin
20 Back To The Table Of Content Denison Vane Pump Division
Vierzon - France