Page 17 - Parker - Vane pumps single, double, triple T6 industrial application
P. 17

ORDERING CODE - T6CC SERIES INDUSTRIAL APPLICATION

            Model No.           T6CC W - 022 - 008 - 1 R 00 - C 1 - 00

            Series                         P1     P2                            Modification
            Severe duty shaft                                                   Mounting W/connection variables
            Cam ring for "P1" & "P2"                                                  P1 = 1" - S = 3"  P1 = 1" - 2"1/2 2)
            (Delivery at 0 PSI & 1200 r.p.m.)                                     P2   1"   3/4" 1)  1"  3/4" 1)
            003 =   3.42 GPM  017 = 18.48 GPM                                    Code  00   01    10    11
            005 =   5.45 GPM  020 = 20.23 GPM
            006 =   6.76 GPM  022 = 22.28 GPM                                   1) for 46 ml/rev. max.
            008 =   8.36 GPM  025 = 25.14 GPM                                   2) for 126 ml/rev. max.
            010 = 10.81 GPM  028 = 27.90 GPM                                    The largest cartridge must be always
            012 = 11.76 GPM  031 = 31.70 GPM                                    mounted in the front.
            014 = 14.58 GPM
                                                                                Seal class
            Type of shaft                   Severe duty (T6CCW only)            1 = S1 (for mineral oil)
            1 = keyed (no SAE)          2 = keyed (SAE BB)                      4 = S4 (for resistant fluids)
            3 = splined (SAE BB)                                                5 = S5 (for mineral oil and fire
            5 = splined (SAE B)
                                                                                             resistant fluids)
            Direct. of rotation (view on shaft end)                             Design letter
            R = clockwise
            L = counter-clockwise                                               Porting combination (see page 30)
                                                                                00 = standard
                       INTERNAL LEAKAGE (TYPICAL)                          NOISE LEVEL (TYPICAL)
                                                                              T6CC - 022 - 022



              Internal leakage qVs [GPM]                       Lp. Noise level [db(A)] 1m ISO 4412














                              Pressure p [PSI]                                 Pressure p [PSI]
            Do not operate the pump more than 5 seconds at any speed or  Double pump noise level is given with each section
            viscosity, if internal leakage is more than 50% of theoretical flow.  discharging at the pressure noted on the curve.
            Total leakage is the sum of each section loss at its operating
            conditions.


                POWER LOSS HYDROMECHANICAL (TYPICAL)                    PERMISSIBLE RADIAL LOAD







              Power loss Ps [HP]                               Load F [Lbs]












                              Pressure p [PSI]                                  Speed n [RPM]
            Total hydrodynamic power loss is the sum of each section at its  Maximum permissible axial load Fa = 180 Lbs
            operating conditions.





                                                                                         Parker Hannifin
                         16                        Back To The Table Of Content          Denison Vane Pump Division
                                                                                         Vierzon - France
   12   13   14   15   16   17   18   19   20   21   22