Page 27 - Gefran - Lift control systems
P. 27

Gefran Spa - Drive & Motion Control Unit • www.gefran.com                        27









                                                      1011      1015       2022      2030       3040      3055
                  Sizes - ADL300-...-2M

           In • Rated output current (fsw = default)
                               @ Uln=230 Vac  A      6         6.8       9.6        13        15         22
           Pn mot                                                                                                    ADL300
           (Recommended motor power, fsw = default)
                               @ Uln=230 Vac  kW    1.1        1.5       2.2        3          4         5.5
           Reduction factor
                                      Kt   (1)      0.95      0.95       0.95      0.95       0.95      0.95
                                    Kalt   (2)      1.2        1.2       1.2        1.2       1.2        1.2
                                                                200% * 3 sec with output frequency more than 3 Hz
           Overload
                                                                   150% * 3 with output frequency 0 ... 3 Hz
           Maximum Switching frequency      kHz                                10
           U2 • Maximum output voltage                              0.98 x Uln  (Uln = AC input voltage)
           f2 • Maximum output frequency    Hz                                300
           IGBT braking unit                              Standard internal (requires external resistor); braking torque 150% MAX  AGL50
          (1) Kt : Fattore di declassamento per   (1) Kt: Derating factor for ambient   (1) Kt : Facteur de déclassement pour  (1) Kt : Herabstufungsfaktor für   (1) Kt : Factor de disminución por
          temperatura ambiente di 50°C (1 %   temperature of 50°C (1% every °C   température ambiante de 50°C (1 %   Raumtemperatur von 50°C (1 % für   temperatura ambiente de 50°C (1 %
          ogni °C superiore a 45°C)  above 45°C)  chaque °C supérieur à 45°C)  jedes °C über 45°C).  cada °C a partir de 45°C)
          (2) Kalt : Fattore di declassamento per  (2) Kalt: Derating factor for installation  (2) Kalt : Facteur de déclassement   (2) Kalt : Herabstufungsfaktor für   (2) Kalt : Factor de disminución para
          installazione ad altitudini superiori a   at altitudes above 1000 meters a.s.l.   pour installation à des altitudes   Installation in höheren Lagen als   instalaciones situadas a una altitud
          1000 metri s.l.m.. Valore da applicare   Value to be applied = 1.2% each 100   supérieures à 1000 mètres au-dessus   1000 Meter über dem Meeresspiegel.  superior a 1000 metros sobre el nivel
          = 1.2 % ad ogni 100 m di incremento  m increase above 1000 m.   du niveau de la mer. Valeur à appliquer  Anzuwendender Wert = 1.2 % alle 100  del mar. Valor a aplicar = 1,2 % por
          oltre i 1000 m.     E.g.: Altitude 2000 m,   = 1.2 % tous les 100 m supplémen-  m Steigerung über 1000 m.   cada 100 m de altitud a partir de los
          Es: Altitudine 2000 m, Kalt = 1,2 % *   Kalt = 1.2% * 10 = 12% derating;   taires au-dessus de 1000 m.   Bsp.: Höhe 2000 m, Kalt = 1,2 % * 10  1000 metros.
          10 = 12% di declassamento; In declas- In derated = (100 - 12) % = 88 % In  Es: Altitude 2000 m, Kalt = 1,2 % * 10  = 12% Herabstufung; bei Herabstu-  Es: Altitud de 2000 m, Kalt = 1,2 % *
          sata = (100 - 12) % = 88 % In           = 12% de déclassement ; In déclassée  fung = (100 - 12) % = 88 % In .  10 = 12% de disminución; In reducida
                                                  = (100 - 12) % = 88 % In                 = (100 - 12) % = 88 % In



                                                                                                                     AVRy


          Declassamento delle prestazioni in regime di sovraccarico (ADL300-...-4 - ADL300-...-2T)
                           Derating values in overload condition • Déclassement des performances en régime de surcharge
               • Herabstufung der Leistungen im Überlastbetrieb • Disminución de las prestaciones del régimen de sobrecarga

          La corrente di uscita in regime di sovraccarico è subordinata al valore
          della frequenza di uscita, secondo quanto indicato nella seguente   OL (% I ) N  Sizes 1...3 (4...22kW)  OL (% I ) N  Sizes 4-5 (30...75kW)
          figura.
          In overload conditions the output current depends on the output
          frequency, as shown in the figure below.   200                           180
          Le courant de sortie en régime de surcharge est conditionné par la va-  150  150
          leur de la fréquence de sortie, comme indiqué dans la figure suivante.
          Der Ausgangsstrom im Überlastbetrieb ist dem Ausgangsfrequenzwert
          unterstellt; siehe die Angaben auf der folgenden Abbildung.
          La corriente de salida en régimen de sobrecarga se subordina al valor                                      AFE200
          de la frecuencia de salida, de tal como se indica en la siguiente figura.  3  F out (Hz)  3    F out (Hz)



          Declassamento delle prestazioni in regime di sovraccarico (ADL300-...-2M)
                                              Derating values in overload condition • Déclassement des performances en régime de surcharge
                                    • Herabstufung der Leistungen im Überlastbetrieb • Disminución de las prestaciones del régimen de sobrecarga
          La corrente di uscita in regime di sovraccarico è subordinata al valore   OL (% I ) N
          della frequenza di uscita, secondo quanto indicato nella seguente
          figura.
          In overload conditions the output current depends on the output   200
          frequency, as shown in the figure below.
          Le courant de sortie en régime de surcharge est conditionné par la va-  150
          leur de la fréquence de sortie, comme indiqué dans la figure suivante.
          Der Ausgangsstrom im Überlastbetrieb ist dem Ausgangsfrequenzwert
          unterstellt; siehe die Angaben auf der folgenden Abbildung.                                                AppEnDix
          La corriente de salida en régimen de sobrecarga se subordina al valor
          de la frecuencia de salida, de tal como se indica en la siguiente figura.  3         F out (Hz)
   22   23   24   25   26   27   28   29   30   31   32