          2-Conductor Female Connectors
          MCS MIDI Classic                                                                                         6
                                                                                                                   387


                                                      With locking levers
               Pin spacing: 5 mm / 0.197 in.      Pin spacing: 5 mm / 0.197 in.              Handling

             0.2–2.5 mm 2      24–12 AWG        0.2–2.5 mm 2      24–12 AWG
          320 V/4 kV/2  16 A   300 V/20 A     320 V/4 kV/2  16 A  300 V/20 A















                           <___ 26,45___>
                          <
                          10 ,6
                          >           <_20,8__ >  _


                                     4,75  <___                 <____ 29,8 ____>  <___ 26,45 ___>  < 2,85  ____
                                                            4,75
                                                    <
                                                      > 5•
                                                ___>
                                      5•  ____>  5,25  <_____ L ____> <___  <__20,8__>  <
                                      >         8,55     > 8  <                                                     6
                                      <  <____L  _
                                     5,25  ___>
         L = (pole no. – 2) x pin spacing + 10 mm                                Operating CAGE CLAMP  S is easy, fast and identical
                                                                                               ®
                                                                                 to that of CAGE CLAMP .
                                                                                              ®
                                                                                 The screwdriver is fully inserted into the operating slot,
                                                                                 holding the CAGE CLAMP  S open. After the conductor
                                                                                                ®
          Pole No.  Item No.         Pack. Unit  Pole No.  Item No.     Pack. Unit  has been inserted into the clamping unit and the screw-
          2-conductor female connector,      2-conductor female connector with locking levers,   driver been withdrawn, the conductor is clamped safely.
                                                                                 Solid and fine-stranded conductors < 0.5 mm  (20 AWG)
                                                                                                          2
          gray                               gray                                are also connected and removed using a screwdriver.
           2        231-2102/026-000     100   2       231-2102/037-000     100
           3        231-2103/026-000     100   3       231-2103/037-000     50
           4        231-2104/026-000     100   4       231-2104/037-000     50
           5        231-2105/026-000     50   5        231-2105/037-000     50
           6        231-2106/026-000     50   6        231-2106/037-000     50
           7        231-2107/026-000     50   7        231-2107/037-000     50
           8        231-2108/026-000     50   8        231-2108/037-000     25
           9        231-2109/026-000     50   9        231-2109/037-000     25
          10        231-2110/026-000     50  10        231-2110/037-000     25
          11        231-2111/026-000     25  11        231-2111/037-000     25
          12        231-2112/026-000     25  12        231-2112/037-000     25
          13        231-2113/026-000     25  13        231-2113/037-000     25
          14        231-2114/026-000     25  14        231-2114/037-000     25
          15        231-2115/026-000     25  15        231-2115/037-000     25
          16        231-2116/026-000     25  16        231-2116/037-000     10
                                                                                 Solid conductors ≥ 0.5 mm  (20 AWG), as well as
                                                                                                2
                                                                                 ferruled, fine-stranded conductors can be terminated by
          2- to 3-pole female connectors – one latch only                        simply pushing them in. Touch contacting is
                                                                                 possible by inserting test probes into the test slots.
                                             Group arrangement without loss of pin spacing
                                             Combining WAGO MCS multipole female connectors
                                             into a single, long male header is a common customer
                                             requirement. This is made possible by using modular
                                             female connectors with integrated end plate, offering the
                                             possibility of side-by-side stacking without needing an
                                             unused pole between connectors for spacing.
                                             Female connectors with built-in end plate require no
                                             extra space, while maintaining the nominal cross-section.
                                             This means: Total length of female connectors is reduced
                                             to “pole no. x” pin spacing!
   384   385   386   387   388   389   390   391   392   393   394