Page 12 - Parker - P1/PD series medium duty axial piston pumps
P. 12

HY28-2665-01/P1/EN                                      Medium Duty Axial Piston Pumps
            Technical Information                                   P1/PD Series



            Torque Limiting Control           “ALT” Control  ( Available on P’045,   separate load sense and
            with Maximum Pressure Limiter     P’060 Models)                      pressure limiter spools which
            AMT, ALT, LOT                                                        results in optimal flow versus
                                              The “ALT” combines the functions    pressure characteristics, and more
            These controls provide the benefit   of a pressure limiter, load sense   productivity for the application. The
            of pressure limiting control , plus    and torque limiter control . The    load sense control function requires   J
                                                                                                Pressure Compensator
                                                                                                   Adjusting Screw
                                                                       A
            the ability to limit the input torque   pressure limiter function limits the   the signal port to be connected to   Z
                                                                        B
            the pump will draw. These controls    maximum pump outlet  pressure.  G  the highest load pressure via a load
            are beneficial when the power     The load sense control function    sense signal line. The control will
                                                                                           "V" VENT PORT
                                                                                           7/16-20UNF-2A SAE J514
            available from the prime mover    requires the vent port to be       match pump output flow and
                                                                                           37° FLARED FITTING
            for the hydraulics is limited; or the    connected to the highest load    pressure to the system demand,
                                                                                                           L
            application power demand has both   pressure via a load sense signal   thus minimizing horsepower losses.
                                                                                                          MAX
            high flow/low pressure and low flow/  line. The control will match pump   The pump will operate in a load  M
                                                                   1.023 [1.023]
                                                              A
            high pressure duty cycles.        output flow and pressure to the    sense mode until the torque
                                                                T
                                                               P
                                              system demand , thus minimizing    limiter  setting is reached, and
            “AMT” Control  ( Available on P’045,   horsepower losses. The pump   then the pump will maintain the
            P’060, P’075, P’100, P’140 Models)    will operate in a load sense mode   P1/PD*** with TORQUE LIMITER
                                                                                 input torque at the pre-selected
                                                                                     CW ORIENTATION
                                                                       TYPICAL DISPLACEMENT vs SYSTEM PRESSURE CURVE
                                              until the torque limiter  setting is   setting. If the system pressure
                                                                                     1800 RPM, LDS
            The “AMT” combines the functions   reached, and then the pump will  CW Rotation  P*075 SHOWN
                                                                   120
                                                                              Arrow reaches the pressure compensa-
            of a pressure limiter and a  torque   maintain the input torque at the    tor setting, then the pump flow will
            limiter control . The pressure limiter   pre-selected setting. If the system   be lowered to the level needed to
                                                                   100
                                                                                     AMT CONTROL
            function can also be controlled   pressure reaches the pressure      maintain the maximum pressure
                                                                  Displacement - %
                                                                   80
            remotely by connecting the vent   compensator setting, then the      setting.
            port to an external  pilot relief valve.    pump flow will be lowered to the     B     V
                                                                   60
            The pump will maintain maximum    level needed to maintain the                         .8mm
            displacement until the torque limiter   maximum pressure setting.   25% Torque Setting
                                                                   40
            setting is reached, and then the                             50% Torque Setting
            pump will maintain the input torque   “L0T” Control  ( Available on P’075,
                                                                   20
            at the pre-selected setting. If the   P’100, P’140  Models)    75% Torque Setting
                                                                                  BG
            system pressure reaches the                             0                                       D3
                                                                                         2500
                                                                         500
                                                                     0
                                                                                     2000
                                                                                              3000
            pressure compensator setting,     The “L0T” combines the functions   1000  1500 System Pressure- psi  3500  4000  4500 D2
            then the pump flow will be lowered    of a pressure limiter, load sense
            to the level needed to maintain    and torque limiter control . This             A          D1
            the maximum pressure setting.     high performance control features        Torque Limiter
                                                                                          AMT Shown
                                                                                     CCW ORIENTATION
                                                                                           P*075 SHOWN
                            P1/PD*** with TORQUE LIMITER      CCW Rotation     P1/PD*** with TORQUE LIMITER               J
                                                                 Arrow
                     TYPICAL DISPLACEMENT vs SYSTEM PRESSURE CURVE   TYPICAL PERCENT of FULL TORQUE vs SYSTEM PRESSURE CURVE  Z
                                   1800 RPM, LDS                                     1800 RPM, LDS
                120                                                                                 TORQUE LOCKNUT
                                                                   100                              1.13 (inch) HEX
                                                                   90                           TORQUE ADJUSTING NUT
                100                                                                  75% Torque Setting  .94 (inch) HEX
                                                                   80          75%
                Displacement - %  60                          P  A  Full Torque - %  T  60  50%           MAX  K
                                                                   70
                 80
                                                                                                           H
                                                                   50
                 40    25% Torque Setting                          40                   50% Torque Setting
                                                                   30   25%                "V" VENT PORT
                       50% Torque Setting                                                  7/16-20UNF-2A SAE J514
                                                                   20                       37° FLARED FITTING
                 20                                                          G       25% Torque Setting
                       75% Torque Setting                          10     B
                                                                                               Pressure Compensator
                 0                                                  0  0  A 500  1000  1500  2000  2500  3000  Adjusting Screw  4500
                                                                                                      4000
                                                                                                  3500
                   0  500  1000  1500  2000  2500  3000  3500  4000  4500
                                System Pressure- psi                              System Pressure - psi
                                                                                              Parker Hannifin Corporation
                                                                                              Hydraulic Pump Division
                                                             0                               Marysville, Ohio USA
                             P1/PD*** with TORQUE LIMITER
                  TYPICAL PERCENT of FULL TORQUE vs SYSTEM PRESSURE CURVE
                                  1800 RPM, LDS
                100
                 90
                                   75% Torque Setting
                 80         75%
                 70
                Full Torque - %  60  50%
                 50
                 40
                 30   25%            50% Torque Setting
                 20
                                   25% Torque Setting
                 10
                  0
                   0  500  1000  1500  2000  2500  3000  3500  4000  4500
                                System Pressure - psi
   7   8   9   10   11   12   13   14   15   16   17