Page 8 - Parker - P1/PD series medium duty axial piston pumps
P. 8

HY28-2665-01/P1/EN                                      Medium Duty Axial Piston Pumps
            Technical Information                                   P1/PD Series


            Control Option “L”
            Load Sensing and Pressure Limiter Control


            These controls feature load sensing and maximum       the pump load sense control will maintain a constant
            pressure compensation. Load sense controls are        pressure drop across the main system throttling
            used to match pump flow and pressure to system         valve, the flow rate will remain constant, independent
            demands, thus minimizing losses due to wasted         of changes in load pressure and pump shaft speed.
            horsepower. The pump automatically adjusts for
            changes in drive speed and load pressures to match
            the pump output flow to the load requirement. Since


                       load sensing and pressure limiter control   loadsensing and pressure limiter control with minimum displacement stop
                                  4 bar maximum                                          4 bar maximum


                    flow                                                   flow






                                pressure                                               pressure




                             B            X
                                                                                  B             X










                BG
                                                                      BG



                                                     D3
                                                                                                          D3
                                                     D2
                                                                                                          D2
                             A               D1
                                                                                  A                D1
                         Load Sensing and                                      Load Sensing and
                     Pressure Limiter Control                              Pressure Limiter Control
                                                                        with Optional Minimum & Maximum
                                                                          Displacement Adjustments and
                                                                             Case-to-Inlet Check Valve
                                                                          (A minimum displacement stop requires
                                                                            the use of a system relief valve.)
            Refer to page 4 for typical control characteristics.


                                                                                              Parker Hannifin Corporation
                                                                                              Hydraulic Pump Division
                                                              6                               Marysville, Ohio USA