Page 112 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 112
112 Inverter System & Power Supply Unit
7.3 Standard connections
FFE200 • Fundamental Front End Regenerative Power Supply Unit
ADV200 - 4 • Basic
IC2 0V24 R-ADV card
IS2
+24V 24Vdc 20mA (typ) 40mA (max)
S3
C3
C2 RS-485 Digital Output 4 = Enable ready mon
12 K2A
11
10 13
Digital
9 14
Output 4
8 IS1
K2M K2A
7 Enable IC1
13 14 13 14
To ADV200 R24 6
Enable Circuits Drive Ready 0V C1
R21
R14 Precharge cmd 5 4
Fsync 500mA GG (cable protection) Circuits R11 3 2 To Drive n
To FFE Auxiliary
W1 1
V1 Sync. Voltage EXP-SYNC-ADV To Drive 3
U1 Keypad
K2M
LR3-.-FFE
F2 D
L3 W
L2 EMI Filter X1 W X2 W V C
L1 X1 V X2 V U
X1 U X2 U
To Drive 2
K1M
PE
F1
L3
X1 L3 X2 L3 L2
X1 L2 X2 L2 L1 To Drive 1
X1 L1 X2 L2
LR3-.-PRC
EN_IN_COM
52 R-PSM card FFE200
0V24
34
EN_IN
23
+24V
35 C (+) D (-)
Fan
U3 V3 W3 PE 31 32
(*)
LR3- . -PRC precharge inductance can be omitted in the following conditions:
Uln DC capacitance Transformer output
inductance
380 Vac... 415 Vac < 150 mF > 20µH
440 Vac ... 500 Vac < 150 mF > 30µH
575 Vac < 115 mF > 30µH
690 Vac < 115 mF > 50µH