Page 42 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 42

42                                 Inverter System & Power Supply Unit





            Overload	according	to	output	frequency	(Synchronous	motor	control)
                     Overload	HD	(ADV200-...-DC-4/4A)                   Overload	LD	(ADV200-...-DC-4/4A)

                                                                   120
              200                                                                        k2
              190
              180                                                  110
              170                   k3                                 k1
      ADV200-DC • DC bus power supply
      ADV200 - 4 • Basic
              160                                                  100
              150
             I out [%]  140  k1  k2                               I out [%]  90
              130
              120
              110
              100                                                  80
               90
               80
               70                                                  70
                0   1   2  3   4   5  6   7   8  9   10              0   1  2   3   4   5  6   7   8  9   10
                                  f [Hz]                                               f [Hz]
                                 _ _ Islow, .... Ifast; __ In                       _ _ Islow, .... Ifast; __ In
                     Overload	HD	(ADV200-...-DC-6/6A)                   Overload	LD	(ADV200-...-DC-6/6A)
                                                                   120
              200                                                                 k2
              190
              180                                                  110
              170                   k3                                 k1
              160
              150                                                  100
             I out [%]  140  k1  k2                               I out [%]  90
              130
              120
              110
              100                                                  80
               90
               80
               70                                                  70
                0   1   2  3   4   5  6   7   8  9   10              0   1  2   3   4   5  6   7   8  9   10
                                  f [Hz]                                               f [Hz]
                                 _ _ Islow, .... Ifast; __ In                       _ _ Islow, .... Ifast; __ In





            Output	frequency	f2
               Sizes       Maximum frequency     Minimum frequency
           ADV200-...-DC  FVCL   FVOL    VF    FVCL    FVOL    VF
           1007 ... 72000  300 Hz  150 Hz  500 Hz
                                                0 Hz   0.5 Hz  1 Hz
           72500 ... 1 MW  200 Hz  150 Hz  200 Hz
          (*) For Brushless motors:
          MAX: FVCL/ FVOL =280 Hz, min: 10% of rated frequency
   37   38   39   40   41   42   43   44   45   46   47