Page 19 - Parker - Rodless Air Cylinders
P. 19
Catalog #AU03-0928/NA Sizing Guidelines
Force Data Rodless Cylinders
Force Data
16mm Bore 20mm Bore
A
Pressure (PSI) Pressure (PSI)
0 30 60 90 0 30 60 90
180 280 63
Static 240 Static 54
150 Dynamic 34 Dynamic 45
Thrust (N) 120 27 Thrust (Lbs) Thrust (N) 200 36 Thrust (Lbs)
160
90
20
120
27
60
30 14 80 18
7
40
9
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Pressure (Bar) Pressure (Bar)
25mm Bore 32mm Bore
Pressure (PSI) Pressure (PSI)
Pressure (PSI)
0 30 60 90 0 30 60 90
420 95 720 162
360 Static 81 600 Static 135
68
300
Thrust (N) 240 Dynamic 54 Thrust (Lbs) Thrust (N) 480 Dynamic 108 Thrust (Lbs)
360
81
180
41
240
54
120
14
60 27 120 27
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Pressure (Bar) Pressure (Bar)
40mm Bore 50mm Bore
Pressure (PSI) Pressure (PSI)
0 30 60 90 0 30 60 90
1800 405
1000 225
Static 1500 Static 338
800 Dynamic 180 1200 Dynamic 270
Thrust (N) 600 135 Thrust (Lbs) Thrust (N) 900 203 Thrust (Lbs)
400
90
135
600
200 45 300 68
0 0 0 0
0 2 4 6 8 0 2 4 6 8
Pressure (Bar)
63mm Bore
Pressure (PSI)
0 30 60 90
2700
2250 Static 508
Dynamic
1800
406
Thrust (N) 1350 305 Thrust (Lbs)
203
900
450 102
0 0
0 2 4 6 8
Pressure (Bar)
Parker Hannifin Corporation
11 Actuator Division
Wadsworth, OH 44281