Page 30 - Linde - HPR-02 Self regulating pump for open loop operation
P. 30

Controllers. LEP. Load Sensing with electro-proportional flow limitation
             and pressure cut-off


            The HPR with LEP-controller offers an on-demand load sensing flow control. The actual volume flow, delivered by the pump can
            be restricted by an electrical signal in certain points of operation. A pressure cut-off function protects the hydraulic system from
            overload.
 01    02     03      04      05      06     07      08      09      10      11
 01                                                                              01
                           LEP mit Standard DA und Standard LS

 02                  Y              LS  P1                                       02
                                                          XD
                                             S2        S1
 03                                                                              03

                                    D1
 04                                                                              04
                                                          X
                           E       P/E      X     T
 05                                                                              05
                           P
                                        0  max
 06                                                                              06
                                    T       U  L

 07                                                                              07
            Without any signal at the solenoid or the LS-port, the pump is swashed back to stand-by position. Both signals at the same time
            are required for the pump to leave stand-by position. The actual swash angle of the pump is determined by the signal with the
                                                                HPR-02-A2-LEP0_Schaltplan_Katalog_v01
                                                        Projekt-Name:
                                                        Projekt-Titel:
            lower target value.                         Dokument-Name:  Schaltplan_LEP
 08                                                     Dokument-Titel:  RA3 - P.Schlee  08
                                                        Projekt-Ersteller:
                                                        Dokument-Ersteller:  19.03.2012 09:50:09
                                                                 RA3 - P.Schlee
                                                        Erstellt am:
                                                        Zuletzt gespeichert:  19.03.2012 10:38:48
                              05
                                                     08
                                             07
                                      06
 01    02   The responding behaviour of the pressure cut-off can be remote-controlled by a hydraulic signal at the XD port as an option. S1 is
                                                             09
              03
                                                                             11
                                                                     10
                      04
            then equipped with an orifice and S2 is sealed. If only the mechanical preset of the PCO is used, S1 is sealed and S2 is not equipped.
            Details, see <<Pump controllers with position feedback. P-axis>>
            Characteristic LEP controller                     LEP-controller
                  2
                         XD
               pmax
                                               ∆p





                                                    1
                                                Qmax
               1  Flow
               2  Pressure
                  Maximum performance range of the pump
                  Actual power demand of the system
                  Regulating ∆p
                  Provided power
                  Pressure cut-off basic setting
                  Characteristic shifting by control signal
                  Electro-proportional flow setting