Page 31 - Linde - HPR-02 Self regulating pump for open loop operation
P. 31
Controllers. ETP. Electro-proportional flow setting, power limitation
and pressure cut-off
The HPR with ETP-controller delivers a volume flow which is exactly proportional to the electric control signal. Superposed, the
controller offers a hyperbolic power limitation, which optimally exploits the power of the prime mover and also protects it from
overload. In addition to this, a pressure cut-off protects the hydraulic system.
03
07
08
09
04
05
06
01 02 The controller is supplied via a feed port "E" at the port plate housing. 10 11
01 01
ETP mit Standard DA und Mode Z1 + Z2 - Schaltung
Z1
02 Y 02
Z2
S4
S2 XD
03 03
S1
04 04
X
05 05
E P X T
P
0 max
06 06
T U L
07 07
The ETP-controller offers a so called hydraulic power mode function. This means, that the regulation begin of the power limitation
HPR-02-A2-ETP0_Schaltplan_Katalog_v01
Projekt-Name:
can be shifted from its mechanical basic setting by means of a remote control port Z1/Z2 at the controller. If the regulation begin
Projekt-Titel:
Schaltplan_ETP
Dokument-Name:
08 Dokument-Titel: RA3 - P.Schlee 08
Projekt-Ersteller:
is intended to be below the basic setting, which means that the pump performance is reduced, then the port Z2 is used, S4 is
RA3 - P.Schlee
Dokument-Ersteller:
Erstellt am:
19.03.2012 10:48:34
Zuletzt gespeichert: 16.03.2012 15:49:26
08
11
09
07
10
01 02 closed. If the mode function is not used at all, or only with the Z1 port, S4 is equipped with an orifice. Z2 is then sealed pressure
03
04
06
05
tight. For details, see <<Pump controllers with position feedback. T-axis>>
The responding behaviour of the pressure cut-off can be remote-controlled by an hydraulic signal at the XD port as an option.
S1 is then equipped with an orifice and S2 is sealed. If only the mechanical preset of the PCO is used, S1 is sealed and S2 is not
equipped. Details, see <<Pump controllers with position feedback. P-axis>>
Characteristic ETP-controller ETP Regler
2
XD
pmax
Z1
Z2
1
Qmax
1 Displacement
2 Pressure
Maximum performance range of the pump
Electro-proportional flow setting
Provided power
Regulation begin power limitation
Pressure cut-off basic setting
Characteristic shifting by control signal
Pressure cut-off basic setting
Characteristic shifting by control signal
31