Page 31 - Linde - HPR-02 Self regulating pump for open loop operation
P. 31

Controllers. ETP. Electro-proportional flow setting, power limitation
             and pressure cut-off


            The HPR with ETP-controller delivers a volume flow which is exactly proportional to the electric control signal. Superposed, the
            controller offers a hyperbolic power limitation, which optimally exploits the power of the prime mover and also protects it from
            overload. In addition to this, a pressure cut-off protects the hydraulic system.
                  03
                                               07
                                                      08
                                                              09
                          04
                                 05
                                        06
    01     02  The controller is supplied via a feed port "E" at the port plate housing.  10  11
 01                                                                             01
                           ETP mit Standard DA und Mode Z1 + Z2 - Schaltung
                                            Z1
 02                    Y                                                        02
                                                        Z2
                                            S4
                                              S2        XD
 03                                                                             03
                                                     S1
 04                                                                             04
                                                        X
 05                                                                             05
                            E       P       X    T
                            P
                                        0  max
 06                                                                             06
                                    T       U  L
 07                                                                             07
            The ETP-controller offers a so called hydraulic power mode function. This means, that the regulation begin of the power limitation
                                                                HPR-02-A2-ETP0_Schaltplan_Katalog_v01
                                                         Projekt-Name:
            can be shifted from its mechanical basic setting by means of a remote control port Z1/Z2 at the controller. If  the regulation begin
                                                         Projekt-Titel:
                                                                     Schaltplan_ETP
                                                         Dokument-Name:
 08                                                      Dokument-Titel:  RA3 - P.Schlee  08
                                                         Projekt-Ersteller:
            is intended to be below the basic setting, which means that the pump performance is reduced, then the port Z2 is used, S4 is
                                                                 RA3 - P.Schlee
                                                         Dokument-Ersteller:
                                                         Erstellt am:
                                                                 19.03.2012 10:48:34
                                                         Zuletzt gespeichert:  16.03.2012 15:49:26
                                                      08
                                                                            11
                                                              09
                                               07
                                                                     10
    01     02  closed. If the mode function is not used at all, or only with the Z1 port, S4 is equipped with an orifice. Z2 is then sealed pressure
                  03
                          04
                                        06
                                 05
            tight. For details, see <<Pump controllers with position feedback. T-axis>>

            The responding behaviour of the pressure cut-off can be remote-controlled by an hydraulic signal at the XD port as an option.
            S1 is then equipped with an orifice and S2 is sealed. If only the mechanical preset of the PCO is used, S1 is sealed and S2 is not
            equipped. Details, see <<Pump controllers with position feedback. P-axis>>
             Characteristic ETP-controller                    ETP Regler
                  2
                         XD
               pmax
                                                 Z1
                                                 Z2
                                                   1
                                               Qmax
                1   Displacement
                2   Pressure
                   Maximum performance range of the pump
                   Electro-proportional flow setting
                   Provided power
                   Regulation begin power limitation
                   Pressure cut-off basic setting
                   Characteristic shifting by control signal
                   Pressure cut-off basic setting
                   Characteristic shifting by control signal
                                                                                                                 31
   26   27   28   29   30   31   32   33   34   35   36