Page 93 - Critical Control flipbook_Neat
P. 93

Falling from Height











           1    What is the name of the       2    What are its specific objectives related to the Priority Unwanted
                critical control for Falling
                                                   Event (PUE)?
                from Height?
          Barriers, Railings and Covered Openings  Creates a physical barrier that prevents a person falling from height at edges or openings
                                             with fall hazards

           3    What are the critical         4    What are the activities       5    What can be sampled from
                control performance
                                                                                      the set of activities for
                                                   within the management
                requirements to meet the           systems that support               verification, providing a
                objectives?                        having the critical control        clear image of the critical
                                                   able to do what is required?       control status?
          Minimum height of 95cm to top rail, toe   Inspection program with daily frequency   Review of inspection documentation;
          boards at least 10cm, no unprotected   for temporary protection and annual for   visual inspection in the workspace to
          gap between toe board and mid rail   permanent protection             validate heights are in specification
          or mid rail and top rail with more than
          50cm

          Temporary barriers that are not fixed to   Daily inspection program to ensure   Review of inspection documentation;
          ground must be placed at least 2m from   handrails or guardrails including hazard   visual inspection in the workspace
          the edge or opening, are clearly visible   signage are in place       to validate distances are correctly
          marked with hazard signage                                            positioned and marked

          Floor opening cover capable to withstand   Inspection program with daily frequency   Review of inspection documentation;
          any potential load, is secured in place   for temporary floor opening protection   visual inspection in the workspace
          and marked with capacity           and annual for permanent protection  to validate  the coverings meet
                                                                                performance requirements
          Handrails, guardrails and coverings are   Inspection program with daily frequency   Review of inspection documentation;
          made of rigid and resistant materials.  for temporary protection and minimum   visual inspection in the workspace to
          Permanent or fixed handrails and   annually for permanent protection  validate adequate materials used
          guardrails need to withstand 1kN


           6    What is the target performance for critical     7    What is the critical control performance
                control?
                                                                     trigger for shutdown, critical control review or
                                                                     investigation?

          Physical barriers of handrails, guardrails or coverings are in   Physical barriers are not meeting the control performance
          place and suitable for 100% of permanent and temporary edges   requirements or are not in place where a fall hazard exists
          and any floor openings























          Creation date: 01/2021 • The latest and only controlled version of this document is available on the HSE intranet.
          © 2021 Holcim - For internal use only