Page 204 - Icon Ridge Hardware & Fixing Technology Catalog
P. 204

Fixing technology

         Nail anchor N-M 6-25 M8/M10 glavanised steel


          Art.-No. 8254 6 25
          The permissible resistance, perm. F, applies to one fixing point.
          A fixing point can be:
          • Single anchor,
          • Anchor pair with axial spacing s > 50 mm or
          • Group of four with s > 50 mm
          If the axial spacing of the anchors in a fixing point is greater than or
          equal to the associated axial spacing between the fixing points, the
          characteristic resistances shall apply for each individual anchor.




          Image 1: Maximum load-bearing capacity




















                                                               Technical Data
                                                               Loads and characteristic values
                                                               Anchoring depth :               25 mm
                                                                            ef
                                                               Permissible load (Bild 1)
                                                               - C12/15 cert. F:               1,43 kN 1
                                                               - C20/25 – C50/60 cert. F:      2,14 kN 1
                                                               Permissible load (Bild 2)
                                                               - C12/15 cert. F:               0,71 kN 1
                                                               - C20/25 – C50/60 cert. F:      0,95 kN 1
                                                               Permissible bending moment cert.M.:  7,3 Nm
                                                               Minimum component thciknessh min :  80 mm
                                                               Mounting details
                                                               Drill hole diameter :           6 mm
                                                                             o
                                                               Through-hole in attachment part :  7 mm
                                                                                        f
                                                               Drill hole depth :              35 mm
                                                                           1
                                                               1  In the N-M Version, if there is shear force, verification of shear
                                                               load with a Lever arm must be produced.













          Position the drill hole     Clean / blow out the      Position the nail anchor   Fit the component
                                      drill hole                and hammer in














        Technical data subject to change.
        Availability subject to country specific rules and regulations.   www.iconridge.com  Source: Theo Förch GmbH & Co. KG                   204