Page 204 - Icon Ridge Hardware & Fixing Technology Catalog
P. 204
Fixing technology
Nail anchor N-M 6-25 M8/M10 glavanised steel
Art.-No. 8254 6 25
The permissible resistance, perm. F, applies to one fixing point.
A fixing point can be:
• Single anchor,
• Anchor pair with axial spacing s > 50 mm or
• Group of four with s > 50 mm
If the axial spacing of the anchors in a fixing point is greater than or
equal to the associated axial spacing between the fixing points, the
characteristic resistances shall apply for each individual anchor.
Image 1: Maximum load-bearing capacity
Technical Data
Loads and characteristic values
Anchoring depth : 25 mm
ef
Permissible load (Bild 1)
- C12/15 cert. F: 1,43 kN 1
- C20/25 – C50/60 cert. F: 2,14 kN 1
Permissible load (Bild 2)
- C12/15 cert. F: 0,71 kN 1
- C20/25 – C50/60 cert. F: 0,95 kN 1
Permissible bending moment cert.M.: 7,3 Nm
Minimum component thciknessh min : 80 mm
Mounting details
Drill hole diameter : 6 mm
o
Through-hole in attachment part : 7 mm
f
Drill hole depth : 35 mm
1
1 In the N-M Version, if there is shear force, verification of shear
load with a Lever arm must be produced.
Position the drill hole Clean / blow out the Position the nail anchor Fit the component
drill hole and hammer in
Technical data subject to change.
Availability subject to country specific rules and regulations. www.iconridge.com Source: Theo Förch GmbH & Co. KG 204