Page 213 - Icon Ridge Hardware & Fixing Technology Catalog
P. 213

Fixing technology

          Bolt-anchors R-XPTII-A4, stainless steel A4

         Extract from the application conditions in the ETA-12/00021 approval
         Overall safety factor taken into account according to ETAG  ( γM and γF)

          Loads and characteristic values   Bolt-anchors R-HPTII-A4  M8    M10    M12    M16


          Characteristic transverse load in uncracked concrete
                                                            [kN]     9,0   16,0   25,0   39,5
                                            C20/25        N Rk,p
          Increasing factors for N Rk,p
                                            C30/37                  1,46   1,37   1,20   1,18
                                            C40/50                  1,91   1,74   1,40   1,37
                                            C50/60                  2,36   2,10   1,60   1,55
          Characteristics shear load capacity        V Rk,s  [kN]   11,7   18,5   24,6   45,5
          Characteristic bending torque              M Rk,s  [Nm]    22     45     72     180
          Axial spacing and edge clearances
          Effective anchoring depth                  h ef   [mm]     47     59     68     85
          Axial spacing                              s cr ,N  [mm]  141    177     204    255
          Edge clearance                             ccr,N  [mm]     71     89     102    128
          Minimum axial spacing cracked / uncracked concrete  s min  [mm]  65  90  110    170
          Minimum edge clearance cracked / uncracked concrete  c min  [mm]  50  60  85    90
          Minimum component thickness                h min  [mm]    100    120     140    170
          Axial spacing and edge clearances at reduced anchoring depth
          Effective anchoring depth                  h ef   [mm]     32     39     48     65
          Axial spacing                              s cr ,N  [mm]   96    177     144    195
          Edge clearance                             ccr,N  [mm]     48     59     72     98
          Minimum axial spacing cracked / uncracked concrete  s min  [mm]  65  115  150   190
          Minimum edge clearance cracked / uncracked concrete  c min  [mm]  50  80  100   120
          Minimum component thickness                h min  [mm]    100    120     100    130
          Mounting data
          Hole diameter                              d o    [mm]     8      10     12     16
          Through-hole in the mounted part           d f    [mm]     9      11     13     18
          Min. drilled hole depth                    h 0    [mm]   55/40 1)  69/49 1)  80/60 1)  100/80 1)
          Anchoring torque                           T inst  [Nm]    15     30     50     100

         1) Reduced anchoring depth (note reduced loads)

































        Technical data subject to change.
        Availability subject to country specific rules and regulations.   www.iconridge.com  Source: Theo Förch GmbH & Co. KG                   213
   208   209   210   211   212   213   214   215   216   217   218