Page 125 - CRS E-booklet 2022
P. 125

123







                    Sl.                                                                           Class of
                   No.     Block Section      LC No.        Km No.        Interlocked or Not       Gate

                    35        RDM-PPZ            52        270/40-44              Yes               SPL
                    36         PPZ-MCI           56      260/46-261/2             Yes               SPL
                    37        MCI-MMZ            57        255/20-22              Yes               SPL
                    38        MCI-MMZ            58        250/34-36              Yes                C

                    39        RECH-RLW           66        229/27-29              Yes                A
                    40        RECH-RLW           68        226/11-13              Yes                A
                    41        RLW-ASAF           70         222/6-8               Yes                A

                    42        RLW-ASAF           71         217/0-1               Yes               SPL
                    43        ASAF-RLT           73         213/0-1               No                 A
                    44         RLT-SKZR          75      207/0-206/29             Yes                A
                    45        VEM-SKZR           78        200/30-32              Yes                A
                    46        VEM-SKZR           79        195/23-25              No                 B2

                    47        SRUR-VEM           80        191/22-24              Yes               SPL
                    48       MKDI-WIRR           89        165/30-32              Yes               SPL
                    49       WIRR YARD           91        160/14-16              Yes               SPL
                    50      MAGH YARD            94        142/26-28              Yes               SPL


               14. OVER AGED SIGNALING LEVER FRAME REPLACEMENT-SANCTION,
                   PROGRESS:
                   Work  of  replacement  of  mechanical  lever  frame  with  panel  interlocking  at  2
                   cabins KZJ MC-1 & MC-2 at KAZIPET is sanctioned in PWP 2016-17 and executing
                   Dy. CSTE/P/SC.

               15. BLANK SIGNALS/UNIT SIGNAL CASES:
                   The  major  contributors  for  signal  blank  cases  and  corrective  action
                   taken is enumerated below: -

               15.1 DEFECTIVE POWER SUPPLY EQUIPMENT:NIL

               15.2   DEFECTIVE CURRENT REGULATOR / ECR RELAY:


                     In order to arrest failures of current regulators; tight sealing of signal units and
                      provision of greased glazed graphite rope to prevent entry of water/rodents
                      and replacement of modified current regulators has been provided.
                    AC LED’s are provided in place of DC LED to improve reliability.
                    LED ECRs for all LED signals is provided.
                    726 nos. of Integrated LEDs are provided so far in 2022-23 (through AAC and
                      works), cumulative progress is 6575 integrated LEDs.