Page 296 - GM E-BOOKLET 2022
P. 296

EXISTING ARRANGEMENT:-


                     AAL/BT  make  VCBs  are  having  air  tank  with  a  cap  (⅜˝)  at  the
            bottom side for draining.


            MODIFIED ARRANGEMENT:-

                    AAL/BT  make  VCBs  air  tank  cap(⅜˝)  is  modified  by  drilling  5mm
            diameter hole and tapping 9mm (suitable for fixing ⅛˝ gauge)  up to a

            depth  of  11mm  to  fix  the  pressure  gauge  with  air  flow  from  air  tank.

            Bottom cover of VCB (AAL only) is modified by enlarging 50mm diameter
            hole in to 70mm diameter hole for visibility of pressure settings of pressure
            gauge.


            WORKS TO BE CARRIED OUT:-


           1.  Remove the bottom cover of VCB (AAL only). Existing 50mm diameter
               hole to be enlarged to 70mm.

           2.  Cap (⅜˝) of air tank to be removed 5mm diameter drilling to be carried
               out. Existing Allen key fixing of cap 9mm tapping (suitable for ⅛˝) to be
               done up to a depth of 11mm.

           3.  Cap(⅜˝) edges to be chamfered upto 1mm on both sides which can
               be tightened with a 20 Size D-Spanner

           4.  Pressure gauge (⅛˝) to be fixed to cap tapping end with Teflon.


            MATERIAL REQUIRED:- 01No. pressure gauge of suitable make (0-10kg/cm²,
            Size ⅛”, dial size 52mm) (SHAVO or any similar make)






















            Existing VCB without Gauge                        Modified with Gauge



                                                             294