Page 301 - GM E-BOOKLET 2022
P. 301

With the help of this test kit we can switch ON the IGBTs of power

            module by providing +15v -15v square wave pulse through optical signal
            generated  by  control  card.  We  can  check  the  healthiness  of  all  sub

            equipments of Power module such as Gate drive card, child card, IGBTs
            etc.
























            5.Modification of moisture drain arrangement:


            Shifting of MCPA reservoir to vertical direction in CCB 2.0 locomotives.

                        The  problem  of  AC-CV  and  MR-CV  is  attributed  to  entry  of

             moisture. As per the observation,  the MPCA reservoir is having  tapping
             into the panel at the bottom most point which is causing the condensate

             water  to  enter  into  panel  along  with  air.  As  per  general  principles  of
             pneumatics,  air  from  the  reservoir  shall  be  taken  from  top  and  drain

             arrangement at the bottom to avoid this problem.  At present, 46 locos
             are  equipped  with  CCB  2.0  and  Shifting  of  MCPA  reservoir  to  vertical

             direction is done in 23 locos.

















            MCPA        reservoir       in    Horizontal  After  modification,  MCPA  reservoir  in
            direction                                        Vertical direction