P. 298

Modification of spare QLM relay as portable testing jig.
























             3.Test parameters programming by PC for testing and data acquisition for
            QLM/OCR (Safety relays).

            Purpose
            To record the testing parameters of safety relay QLM and OCR digitally.


            Advantage
            To test, check and record the relay testing parameter like pick up, drop

            out of relay and mill volt drop of interlocks can be done.
            Test data report recorded by type of relay, date, by relay serial no, by

            loco no and by monthly records

            Testing relays

            QLM and OCR


            Testing periodicity: IA, IB, IC, TOH and IOH schedule.
            Record of type of relay, loco no, Sl.
            No.  date,  time,  pick  up  and  drop  Record of mill volt drop of interlocks
            out values