Page 302 - GM E-BOOKLET 2022
P. 302

6.Repairing of Electronic cards


            Following  electronic  cards  of  WAG-7  and  WAG-9  locomotives  were
            repaired in house by replacing the defective components.


                            Locomo
            Equipmen                                   Loco                                         Cost of the
              t failed         tive        Make         No.            Attention paid               equipment
                               Type

                                                                Pulse transformer on
             INVERTER
              GDU  of        WAG 7          AAL       27787     GDU card defective, it              2,50,000 /-
                                                                was replaced with
                 SIV
                                                                rewound transformer.
                                                                Resistor of I-4 channel
               INPUT                       MEDH                 defective, resistor

             CARD of         WAG 7            A       28437     replaced with good                   65,000 /-
               MPCS
                                                                one.
                                                                Reed relay (QCON) of
                MCU                                             MCU defective, it was
                Card         WAG 7          AAL       28706     replaced with good                  4,50,000 /-
                                                                one.

                                                                PMI card of module
               Power                                            defective, it was
            module of  WAG 9                BHEL      31346                                         18,00,000 /-
                 SR                                             replaced with good
                                                                one.
                                                                SID card of module
               Power
            module of  WAG 9                BHEL      31969     defective, it was                   18,00,000 /-

                 SR                                             replaced with good
                                                                one.
             IO  Card                                           Reed relay on I/O card
             (URB512)        WAG 9          BHEL      31730  defective, it was                       75,000 /-
              of VCU                                            replaced with new one.
                                                                Defective capacitors

             PS CARD         WAG 9         MEDH       31557     (Sic-safco make)                     65,000 /-
                of SR                         A                 replaced with Keltron
                                                                make capacitors.
                                                                Repairing of 02 GDU
                GDU                                                                                  2,60,000/-
               Cards         WAG 9          AAL       32033  cards of AAL Auxiliary                  per card
                                                                converters

                                                       32326    Repairing of 02 EBVs of              3,50,000/-
                EBV          WAG 9          CCB          &
                                                       31427    pneumatic system                      per unit

                                                             300