Page 65 - GM booklet 2019 test
P. 65

3.  In  MMTS  Phase  -  II  work,  new  double  line  with  automatic  signalling
                   between BMO-MED station commissioned with following installations.

                        Existing panel interlocking replaced with Electronic interlocking of M/s Medha
                          Servo Drives Pvt. Ltd. at BMO, GDPL & MED stations.
                        Existing  absolute  block  working  between  BMO-GDPL  &  GDPL-MED  is
                          replaced with Automatic signalling by providing MSDAC of M/s Medha Servo
                          Drives Pvt. Ltd.
                        Existing  push  button  token  less  block  instrument  between  MED-MOB  is
                          replaced with UFSBI of Deltron Make along with HASSDAC.















               4.  In  connection  with  New  Line  between  AKE-Medak,  remodeling  of  yard  carried
                       out at AKE. The following assets have been installed:

                        Existing panel interlocking replaced with Electronic interlocking of M/s Medha
                          Servo Drives Pvt. Ltd.
                        Existing  IPS  of  Amara  raja  make  (old  RDSO  Spn  165/2000)  replaced  with
                          Statcon make (Latest RDSO Spn 165/2012).