The modules on myPNOZ are also possible to form multiple safety zones, which
easily connected using BUS independently monitor plant sections that operate
connectors. Plus the whole separately. This helps to increase the availability of the
system is supplied with plant because machine parts can be shut down
power via the head module. independently from each other.
As a result, only the head The slimline 17.5mm head module already has a
module needs to be higher-level safety function. This works on all outputs,
connected to the power regardless of any other potential safety zones. The
supply, which reduces wiring. output modules either switch immediately or with a
So the plant can be time delay and are available with relay or
commissioned quicker and semiconductor outputs. myPNOZ enables safety
can also be optimised with a functions to be AND / OR linked, enabling customised
view to maintenance costs: if applications.
just one module needs to be Pilz says myPNOZ represents an efficient, safe
swapped, individual modules solution for mechanical engineering. What’s more the
can be exchanged safety relay can be used in various industries. Users
immediately without benefit with safety applications of simple to average
dismantling the whole complexity, when two to a maximum of 16 safe input myPNOZ.
system. functions are to be monitored, without using
engineering software.
MORE INFORMATION: www.mypnoz.com Your new safety relay.
signal confusion, CTM switches can be sited just
40mm apart. At its price point it is unbeatable for this
level of security and flexibility in such a small switch.”
Euchner’s CTM boasts a wide range of functionality
that makes it perfect for almost all situations. The bi-
stable guard locking function, with a locking force in
excess of 1000N, means that
Discover the new generation of our safety relays. Experience the limitless
in the event of a power failure
potential combinations, clever product features and innovative myPNOZ
or shut-down, the switch
remains in it’s previous state, Creator for yourself.
making it much safer for Create your safety – individual, tailor-made, easy.
applications where body
Find out more:
access is required or where
clean-down or maintenance
procedures are ideally carried out
without power being applied to the machine. When
the operating voltage of the switch is removed, the
guard locking always remains in its current state. The
guard door is either locked or it can be opened and
closed as required. For ease of operational
monitoring, the CTM features two multi-colour LED
displays that are visible from either side of the switch
allowing the current status of the switch to be
easily checked at a glance, even from a distance.
MORE INFORMATION: www.euchner.co.uk
January/February 2021 • INDUSTRIAL TECHNOLOGY
Pilz_AD_myPNOZ_en_105x297_print_version.indd 1 25/01/2021 10:57:26