Page 43 - Pharmaceutics IV (02-06-01305)
P. 43
Pharmaceutical requirements
Clarity (for solutions)
Source & contaminants
• Contaminants include dust, cloth fibers,
glass fragments, material leached from the
glass or plastic container or seal.
• Sources of particulate matter include the
raw materials, processing and filling
equipment, the container, and
environmental contamination.
79
Pharmaceutical requirements
Clarity (for solutions)
Complications
• IV: pulmonary embolism
• IV: infusion phlebitis
It has been shown that the development of infusion phlebitis (vein
inflammation) may be related to the presence of particulate matter in
intravenous fluids.
• IM: injection granuloma/muscle granuloma
80 40
Salma E. EL-Habashy