Page 90 - Pharmaceutics IV (02-06-01305)
P. 90

Parenterals: Quality control testing

    Container-closure integrity/ Leaker testing

• The packaging system should be closed or sealed in such a manner
    as to prevent contamination or loss of contents.

• It’s specifically conducted for glass ampoules.
• It’s a nondestructive test (whole-batch test).

173

  Parenterals: Quality control testing

      Container-closure integrity/ Leaker testing

 Methylene blue test:
 • Ampoules that have been sealed by fusion must be tested to ensure

     that a hermetic seal was obtained.
 • It is performed by immersing the ampoules in a dye solution, such as

     1% methylene blue, and applying vacuum for a minimum of 15
     minutes then releasing vacuum. Next, the ampoules are washed,
     where defective ampoules will contain blue solution.

174

Salma E. EL-Habashy                                                      87