Parenterals: Quality control testing
Container-closure integrity/ Leaker testing
• The packaging system should be closed or sealed in such a manner
as to prevent contamination or loss of contents.
• It’s specifically conducted for glass ampoules.
• It’s a nondestructive test (whole-batch test).
173
Parenterals: Quality control testing
Container-closure integrity/ Leaker testing
Methylene blue test:
• Ampoules that have been sealed by fusion must be tested to ensure
that a hermetic seal was obtained.
• It is performed by immersing the ampoules in a dye solution, such as
1% methylene blue, and applying vacuum for a minimum of 15
minutes then releasing vacuum. Next, the ampoules are washed,
where defective ampoules will contain blue solution.
174
Salma E. EL-Habashy 87