250 FULLY BONDED BITUMEN TANKING
      • Substrate: site specific.
      • Primer: Required.
      • Bitumen sheet: Generally to BS 743.
          - Weight (minimum): 3.8 kg/m².
      • Number of layers: Three, laid to break joint.
      • Bonding: Hot applied bonding compound.
      • Joints: Side and end laps minimum 100 mm and 150 mm respectively.
          - Sealing: Fully bond.
      • Subsequent layers: Apply as soon as possible.

290 HIGH DENSITY POLYETHYLENE/ POLYPROPYLENE STUDDED CAVITY DRAIN MEMBRANE
      • Substrate: site specific.
          - Preparation: Primer.
      • Manufacturer: Contractor's choice.
          - Product reference: Agrément certified.
      • Stud height: site specific.
      • Colour: site specific.
      • Fixing: In accordance with manufacturer's recommendations.
          - Fasteners: In accordance with manufacturer's recommendations.
             Fixing centres: In accordance with manufacturer's recommendations.
             Sealing: Taped flush with the membrane.
      • Joints: Lapped minimum three studs.
          - Sealing: Butyl rubber sealant between last two rows of studs and joints overtaped.

      • Drainage components: site specific.
      • Accessories: site specific.

295 GEOCOMPOSITE STUDDED CAVITY DRAINAGE/ VENTING MEMBRANE
      • Substrate: site specific.
      • Manufacturer: Contractor's choice.
          - Product reference: Contractor's choice.
      • Stud height: site specific.
      • Fixing: As manufacturer's recommendations.
          - Fixing centres: As manufacturer's recommendations.
      • Joints: Seal with waterproof tape or rope.
      • Exposed edges and corners: Seal with geotextile fabric to prevent silt entering the
          core.
      • Accessories: site specific.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01