Page 277 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 277

WORKMANSHIP

310 WORKMANSHIP GENERALLY
      • Condition of substrate:
          - Clean and even textured, free from voids and sharp protrusions.
          - Moisture content: Compatible with damp proofing/ tanking.
      • Air and surface temperature: Do not apply sheets if below minimum
          recommended by membrane manufacturer.
      • Condition of membrane at completion:
          - Neat, smooth and fully supported, dressed well into abutments and around
             intrusions.
          - Completely impervious and continuous.
          - Undamaged. Prevent puncturing during following work.
      • Permanent overlying construction: Cover membrane as soon as possible.

335 PRIMERS
      • Manufacturer: Contractor's choice .
          - Product reference: site specific .
      • Coverage per coat (minimum): As recommended for the purpose by membrane
          manufacturer .
      • Curing: Allow to dry thoroughly before covering.

340 HOT APPLIED BONDING COMPOUNDS
      • Type: Oxidized bitumen to BS 3690-2.
          - Grade: As recommended by membrane manufacturer for the conditions and
             type of surface .
      • Application: Continuous even coating to provide full bonding over whole surface.
          Do not overheat.

345 COLD APPLIED BONDING COMPOUNDS
      • Type and application: As recommended for the purpose by the membrane
          manufacturer.

350 ANGLES IN BONDED DAMP PROOFING/ TANKING
      • Preformed rot proof fillet to internal angles:
          - Size (minimum): 50 x 50 mm, splay faced.
          - Bedding: Bitumen mastic or bonding compound.
      • Reinforcing strip to all angles:
          - Material: As damp proofing/ tanking.
          - Width (minimum): 300 mm.
          - Timing: Apply before main sheeting.
      • Dressing of main sheeting onto adjacent surfaces (minimum): 100 mm.

360 JUNCTIONS WITH PROJECTING DPCS/ CAVITY TRAYS
      • Adjoining surfaces: Clean and dry.
      • Dpcs/ Cavity trays: Lap and fully bond/ seal with sheeting.
          - Laps (minimum): 150 mm.
          - Bonding/ Sealing: site specific.