Drainage & Piped Services Standard Specification
Version 2014-1
Internal Gravity Rainwater Drainage System - Type A
System Performance: Design of gravity rainwater drainage system type A.
System manufacturer: [Polypipe Terrain Ltd. or equal and approved]
Roof gutters:
Gutters:
Gutter types: By others
Jointing:
Electrical continuity:
Supports:
Brackets:
Fixings:
Rainwater outlets: Gravity rainwater outlets.
Internal rainwater pipework:
Rainwater downpipes:
Downpipe types: Unplasticized polyvinyl chloride (PVC-U) above ground drainage pipelines type A.
Jointing: Integral push fit ring seal sockets and Solvent weld.
Supports:
Brackets and clips: Brackets and clips for above ground drainage pipelines type B.
Fixings: Stainless steel screws.
Warning pipes: Required
System accessories: Identifying pipework type A.
Execution: Installation of rainwater drainage generally and Access for testing and maintenance of
rainwater drainage system.
System Completion:
Rainwater drainage internal pipework test – England, Wales, Ireland and Northern Ireland
Preparation: Temporarily seal open ends of pipework with plugs.
Test apparatus: Connect a ‘U’ tube water gauge and air pump to pipework via a plug.
Testing: Pump air into pipework until gauge registers 38 mm.
Required performance: After a period for temperature stabilization, maintain the pressure of 38
mm without loss for at least 3 minutes.
Rainwater drainage internal pipework test – Scotland
Testing:
Standard: To BS EN 12056-3, National annex NE.4.2.
Method: Air pressure test.
Required performance: Pipework to withstand constant pressure of 38 mm water gauge for 3
minutes.
Rainwater drainage system maintenance instructions type A
Printed instructions: Submit at completion.
Contents: Recommended procedures for maintenance of the rainwater installation, including full
details of recommended inspection, cleaning and repair procedures.
3/6
McDonalds Restaurants Ltd