Page 39 - McD_ROTF DRAINAGE & PIPED SERVICES_Neat
P. 39
Drainage & Piped Services Standard Specification
Version 2014-1
Rainwater drainage system pre-handover checks type A
Construction rubbish, debris, swarf, temporary caps and fine dust which may enter the rainwater
system: Remove. Do not sweep or flush into the rainwater system.
Access covers, rodding eyes, outlet gratings and the like: Secure complete with fixings.
Documentation type A
Operating and maintenance instructions:
Scope: Submit for the system giving optimum settings for controls.
Product information: Include product description, date of purchase, performance
characteristics, application (suitability for use), method of operation and control, and
cleaning and maintenance requirements.
Format: Paper copy.
Number of copies: Two
Record drawings:
Content: Location, size and route of drainage services and Location of outlets.
Format: Electronic.
Number of copies: Two
Submittal date: At handover.
System Performance
Design of gravity rainwater drainage system type A
Design: Complete the design of the rainwater drainage system.
Standards: In accordance with E&W Building Regulations Approved Document H, H3, Section 1 and
To BS EN 12056-3, clauses 3–7, Annex A and National Annexes.
Design parameters:
Roof and gutter construction and finish:
Design life of building: 50 years.
Design rate category: Category 2 to BS EN 12056-3, NB.2.1 and Category 3 to BS EN 12056-
3, NB.2.1.
Available capacity of existing below ground drainage (maximum):
Requirement: Submit proposals including detailed design drawings, technical information,
calculations and manufacturers’ literature.
Products
Gravity rainwater outlets
Manufacturer: Aco Fulbora or equal and approved
Roof construction:
Form: Manufacturer's standard.
Roof insulation thickness: Submit proposals.
Material: Submit proposals.
Grating: Flat.
3/7
McDonalds Restaurants Ltd