Page 41 - McD_ROTF DRAINAGE & PIPED SERVICES_Neat
P. 41
Drainage & Piped Services Standard Specification
Version 2014-1
Requirement: Install pipework and gutters with adequate clearance to permit testing, cleaning and
maintenance, including painting where necessary.
Access fittings and rodding eyes: Position so that they are not obstructed.
Installing gravity rainwater drainage outlets
Fixing: Secure. Fix before connecting pipework.
Method: Submit proposals.
Junctions between outlets and pipework: Accommodate movement in structure and pipework.
Installing identification on pipework
Application of basic identification colour: Coloured bands as BS 1710 clause 3.3.
Safety colour identification: On or next to the colour bands.
Information: Colour bands as BS 1710 appendix D.
Direction of flow: Indication arrow.
System Completion
Rainwater drainage internal pipework test – England, Wales, Ireland and Northern Ireland
Preparation: Temporarily seal open ends of pipework with plugs.
Test apparatus: Connect a ‘U’ tube water gauge and air pump to pipework via a plug.
Testing: Pump air into pipework until gauge registers 38 mm.
Required performance: After a period for temperature stabilization, maintain the pressure of 38
mm without loss for at least 3 minutes.
Rainwater drainage internal pipework test – Scotland
Testing:
Standard: To BS EN 12056-3, National annex NE.4.2.
Method: Air pressure test.
Required performance: Pipework to withstand constant pressure of 38 mm water gauge for 3
minutes.
Rainwater drainage system maintenance instructions type B
Printed instructions: Submit at completion.
Contents: Recommended procedures for maintenance of the rainwater installation, including full
details of recommended inspection, cleaning and repair procedures.
Rainwater drainage system pre-handover checks type B
Construction rubbish, debris, swarf, temporary caps and fine dust which may enter the
rainwater system: Remove. Do not sweep or flush into the rainwater system.
Access covers, rodding eyes, outlet gratings and the like: Secure complete with fixings.
Documentation type B
Operating and maintenance instructions:
Scope: Submit for the system giving optimum settings for controls.
3/9
McDonalds Restaurants Ltd