         WC provision must be in line with the Technical
         Handbook requirement for all projects.



         Table  3.8  in  section  3.12.5  ‘Provision  for  public  in  entertainment  &  assembly  buildings’  of  the  ‘Environment’  Non  Domestic  Technical
         Handbook states:
          Building Type (2)        Sex     Number of People         Number of WCs            Number of Urinals
          Restaurants, cafes, canteens   male  1-400 [6]            1 for every 400, or part   1 for every 50 males, or
          and fast food outlets (where                              thereof                  part thereof
          seating is provided)             over 400                 plus 1 for each extra 250
          Cleaners Sink                                             males, or part thereof
                                   female  1-20                     2
                                           21-50                    3
                                           51-100                   4
                                           101-150                  5
                                           151-200                  6
                                           over 200                 plus 1 for each extra 100
                                                                    females or part thereof


         Employee Toilets


         Employee toilet provision must be in line with
         the Technical Handbook requirement  for all
         projects.



         Table 3.5 in section 3.12.2 ‘Provision for staff’ of the ‘Environment’ Non Domestic Technical Handbook states:

          Gender               Staff Numbers        WC                  WHB                  Urinals
          Male                 1-5                  1                   1                    1
                               16-30                2                   2                    1
                               31-45                2                   2                    2
                               46-60                3                   3                    2
                               61-75                3                   3                    3
                               76-  90              4                   4                    3
                               91- 100              4                   4                    4
                               over 100             1 additional WC, WHB and urinal for every additional 50 males or part thereof
          Female (also male    1- 5                 1                   1
          where no urinals are   6 - 25             2                   2
          provided)
                               over 25              1 additional WC and WHB for every additional 25 females (or males), or part
                                                    thereof




          D4.26          Toilet Facilities                   5.0                        10 October 2017