Page 89 - CRS Engineering
P. 89
Proforma for Joint Inspection on R. A. T.
For the Year 2020-21
Si Description Remarks
No
I General Particulars of RAT
1 Name of the tank Naiducheruvu of Kammakothuru
2 District Chittoor District
3 Name of the Village and Mandal Kammakothuru Village ,Srikalahasti Mandal
4 Latitude & Longitude Lat 13° - 46' - 50" Long 79° - 40' - 30"
5 Affected Railway Bridge and Km The Tank Lies in-between Bridge No:- 63 & 53 /
35-38
6 Railway section in between stations Akkurthy and Yellakaru
7 Distance from Railway Bridge to weir Railway line Crosses the tank bund and fore shore
( Along the Course of Nailah ) of the tank.
II Standard Hydraulic Details
1 Catchment Area 23.40 Sq miles
2 Capacity of the tank 105.70 MCFT
3 Lowest Bed Level + 47.09M
4 Full Tank Level ( F.T.L ) +50.14M
5 Maxim Water Level ( M.W.L ) +50.74M
6 Danger Level ( D.L ) +51.14M
7 Top of Bund Level ( T.B.L ) +51.64M
8 Top Width of the Bund 1.20M ,3.00 M, ( Present Top Width )
9 Side Slopes AT FRONT:- 1 1/2 : 1 , AT REAR :- 2:1
10 Area of Submergence at FTL -
11 Area of Submergence at MWL -
12 Are there any tanks in the Catchment of NO
this tank
13 Are these tanks also classified as RATs -
14 Names and details of these tanks -
III Surplus Weir -
1 Number of Surplus Weirs FOUR NUMBERS ONLY
2 Lengths of Surplus Weir 10.00 M
3 Type of Surplus Weir B.C WEIR
4 Design Discharge -
IV Sluices -
FOUR NUMBERS ONLY ( 4 NosOnly )
1 Number of Sluices
2 Location of Sluices
3 Maximum designed discharge 2.50 CUSECS
FUNCTIONAL
4 Functional or not
V A) Inspection details
^5-02-2020
i)Date of Inspection
ii)Name& Designation of the inspection 1) Sri. C. Willson Babu,
Assistant Divisional engineer,
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech.,
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K Rajesh,B.Tech.,
Assistant Executive Engineer,
Irrigation Section
SRIKALAHASTI