Page 91 - CRS Engineering
P. 91
Proforma for Joint Inspection on R. A. T.
For the Year 2020-21
SI Description Remarks
No
I General Particulars of RAT
1 Name of the tank Jingilapalem Tank
2 District Chittoor District
3 Name of the Village and Mandal Jingilapalem Village ,Srikalahasti Mandal
4 Latitude & Longitude Lat 13° - 45' - 42" Long 79° - 39' - 10"
5 Affected Railway Bridge and Km The Tank Lies in-between Bridge No;- 70&57 /
24-26
6 Railway section in between stations Akkurthy and Yellakaru
7 Distance from Railway Bridge to weir 5.00 KM from the Railway line to the tank.
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 0.83 Sq miles
2 Capacity of the tank 18.36 MCFT
3 Lowest Bed Level + 9.80M
4 Full Tank Level ( F.T.L ) + 13.71M
5 Maxim Water Level ( M.W.L ) -I-14.40M
6 Danger Level ( D.L ) + 15.27M
7 Top of Bund Level ( T.B.L ) + 15.77M
8 Top Width of the Bund 1.20M ,1.50 M , 3.00 M , ( Present Top Width )
9 Side Slopes AT FRONT:- 1 1/2 : 1 , AT REAR 2:1
10 Area of Submergence at FTL -
11 Area of Submergence at MWL -
12 Are there any tanks in the Catchment of NO
this tank
13 Are these tanks also ciassiriea as rats -
14 Names and details of these tanks -
III Surplus Weir -
1 Number of Surplus Weirs THREE NUMBERS ONLY ( 3 Nos Only )
1enqth<5 of Surplus Weir No:-1=18.50M , No:-2= 10.00 M
2
3 Type of Surplus Weir B.C WEIR
4 Design Discharge 109.34 Cusecs
IV Sluices -
FOUR NUMBERS ONLY ( 4 Nos Only )
1 Number of Sluices
2 Location of Sluices
3 Maximum designed discharge 2.50 CUSECS
FUNCTIONAL
4 Functional or not
V A) Inspection details
^.5-02-2020 ~
i)Date of Inspection
i)Name& Designation of the Inspection 1) Sri. C. Willson Babu,
Assistant Divisional Engineer .
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech.,
Deputy Executive Engineer .
Irrigation Sub Division ~
3) Sri. K Rajesh,B.Tech.,
Assistant Executive Engineer,
Irrigation Section
SRIKALAHASTI