Page 93 - CRS Engineering
P. 93
Proforma for Joint Inspection on R. A. T.
For the Year 2020-21
Description Remarks
SI
No
General Particulars of RAT
Kothagunta Tank
Name of the tank
Chittoor District
District
Name of tlie Village and Mandal Kothagunta Village ,Srikalahasti Mandal
Latitude & Longitude Lat 13° - 45' - 58" Long 79° - 40' - 02'
Affected Railway Bridge and Km The Tank Lies in-between Bridge No:- 70&57 /
24-26
Railway section in between stations Akkurthy and Yellakaru
Distance from Railway Bridge to weir lOOM from the Railway line to the tank.
( Along the Course of Nallah )
II Standard Hydraulic Details
1 Catchment Area 0.68 Sq miles
2 Capacity of the tank 14.90 MCFT
3 Lowest Bed Level + 97.90M
Full Tank Level ( F.T.L ) +100.00M
Maxim Water Level ( M.W.L ) +100.60M
Danger Level ( D.L ) -1-101.20M
7 Tod of Bund Level ( T.B.L ) + 101.50M
Top Width of the Bund 1.20M .1.50 M , ( Present Top Width )
8
AT FRONT:- 1 Va : 1 . AT REAR :- 2:1
Side Slopes
10 Area of Submergence at FTL
11 Area of Submergence at MWL
12 Are there any tanks in the Catchment of NO
this tank
LI lia LOI IIS.
13 Are tanks also classified as RATs
14 Names and details of these tanks
III Surplus Weir
Number of Surplus Weirs ONE NUMBER ONLY ( 1 No Only )
Lengths ofSurplus Weir 10.00 M
Type of Surplus Weir B.C WEIR
342 Cusecs
Design Discharge
IV Sluices
TWO NUMBERS ONLY ( 2 Nos Only )
Number of Sluices
Location of Sluices
Maximum designeddischarge_ 2.50 CUSECS
FUNCTIONAL
Functional or not
A) Inspection details
^.5-02-2020
i)Date of Inspection 1) Sri. C. Willson Babu,
ii)Name& Designation of the Inspection
Assistant Divisional Engineer .
South Central Railway
RENIGUNTA
2) Sri. C.Adinarayana Naidu, B.Tech..
Deputy Executive Engineer,
Irrigation Sub Division
3) Sri. K Rajesh^.Tech.,
Assistant Executive Engineer ,
Irrigation Section
SRIKALAHASTI