Page 32 - dust collection systems
P. 32
advanced cleaning system, as pulse is injected directly into
the bag, secondary air flow is just 1-2 times the primary air
flow.
As the filter media is not flexed as extensively as in the
traditional cleaning system, low pressure (20 to 40 psi)
advanced cleaning system increases life of filter bags.
However, the conventional cages cannot be used in advanced
cleaning system as there is a tendency for them to bend due
to the excessive length. Higher thickness wires are used for
cages when the height of bag or cage is 6 m or more. This
higher thickness ensures straightness (spacing between
bags) of the bags which are freely suspended from the tube
sheet.
The critical factor for providing thorough bag cleaning and to
prevent damage to venturis and bags is to make sure that the
hole/orifice/nozzle in the blow pipe (compressed air
manifold) are properly aligned above the filter bags. The
holes should also point straight into the bags. if holes of the
blow pipe are not properly aligned above the filter bags, it
may damage venturis. Rotation of the blow pipe could cause
the compressed air pulse to strike the side of the bag near