Page 32 - dust collection systems
P. 32

advanced cleaning system, as pulse is injected directly into
               the bag, secondary air flow is just 1-2 times the primary air

               flow.











               As the filter media is not flexed as extensively as in the

               traditional cleaning system, low pressure (20 to 40 psi)

               advanced cleaning system increases life of filter bags.





               However, the conventional cages cannot be used in advanced

               cleaning system as there is a tendency for them to bend due

               to the excessive length. Higher thickness wires are used for

               cages when the height of bag or cage is 6 m or more. This

               higher thickness ensures straightness (spacing between

               bags) of the bags which are freely suspended from the tube

               sheet.





               The critical factor for providing thorough bag cleaning and to

               prevent damage to venturis and bags is to make sure that the

               hole/orifice/nozzle in the blow pipe (compressed air

               manifold) are properly aligned above the filter bags. The

               holes should also point straight into the bags.  if holes of the

               blow pipe are not properly aligned above the filter bags, it

               may damage venturis. Rotation of the blow pipe could cause

               the compressed air pulse to strike the side of the bag near
   27   28   29   30   31   32   33   34   35   36   37