           Mechanical joints shall be installed only in underground  tube ends shall be reamed to the full inside diameter of the
           systems  unless  otherwise  approved.  Joints  shall  be  tube end. Joint surfaces shall be cleaned. Fluxes for solder-
           installed  in  accordance  with  the  manufacturer’s  instruc-  ing  shall  be  in  accordance  with  ASTM  B813  and  shall
           tions.                                                become  noncorrosive  and  nontoxic  after  soldering.  The
                                                                 joint shall be soldered with a solder conforming to ASTM
           P3003.3.2  Solvent  cementing.  Joint  surfaces  shall  be
           clean  and  free  from  moisture.  Solvent  cement  that  con-  B32.
           forms to ASTM D2235 or CSA B181.1 shall be applied to  P3003.6.4  Threaded  joints.  Threads  shall  conform  to
           joint surfaces. The joint shall be made while the cement is  ASME  B1.20.1.  Pipe-joint  compound  or  tape  shall  be
           wet.  Joints  shall  be  made  in  accordance  with  ASTM  applied on the male threads only.
           D2235, ASTM D2661, ASTM F628 or CSA B181.1. Sol-   P3003.7  Steel.  Joints  between  galvanized  steel  pipe  or  fit-
           vent-cement  joints  shall  be  permitted  above  or  below  tings shall comply with Sections P3003.7.1 and P3003.7.2.
           ground.
                                                                 P3003.7.1  Threaded  joints.  Threads  shall  conform  to
           P3003.3.3  Threaded  joints.  Threads  shall  conform  to  ASME  B1.20.1.  Pipe-joint  compound  or  tape  shall  be
           ASME B1.20.1. Schedule 80 or heavier pipe shall be per-  applied on the male threads only.
           mitted to be threaded with dies specifically designed for
           plastic  pipe.  Approved  thread  lubricant  or  tape  shall  be  P3003.7.2 Mechanical joints. Joints shall be made with
           applied on the male threads only.                     an approved elastomeric seal. Mechanical joints shall be
                                                                 installed  in  accordance  with  the  manufacturer’s  instruc-
         P3003.4 Cast iron. Joints between cast-iron pipe or fittings  tions.
         shall comply with Sections P3003.4.1 through P3003.4.3.
                                                              P3003.8 Lead. Joints between lead pipe or fittings shall com-
           P3003.4.1 Caulked joints. Joints for hub and spigot pipe  ply with Sections P3003.8.1 and P3003.8.2.
           shall be firmly packed with oakum or hemp. Molten lead
           shall be poured in one operation to a depth of not less than  P3003.8.1 Burned. Burned joints shall be uniformly fused
                                                        1
           1 inch (25 mm). The lead shall not recede more than  / 8  together into one continuous piece. The thickness of the
           inch (3 mm) below the rim of the hub and shall be caulked  joint shall be not less than the thickness of the lead being
           tight. Paint, varnish or other coatings shall not be permit-  joined. The filler metal shall be of the same material as the
           ted on the jointing material until after the joint has been  pipe.
           tested and approved. Lead shall be run in one pouring and  P3003.8.2  Wiped.  Joints  shall  be  fully  wiped,  with  an
           shall be caulked tight.                               exposed surface on each side of the joint not less than  / 4
                                                                                                              3
                                                                                                      3
           P3003.4.2 Compression gasket joints. Compression gas-  inch (19 mm). The joint shall be not less than  /  inch (9.5
                                                                                                       8
           kets for hub and spigot pipe and fittings shall conform to  mm) thick at the thickest point.
           ASTM C564. Gaskets shall be compressed when the pipe  P3003.9 PVC plastic. Joints between PVC plastic pipe or fit-
           is fully inserted.                                 tings  shall  comply  with  Sections  P3003.9.1  through
           P3003.4.3 Mechanical joint coupling. Mechanical joint  P3003.9.3.
           couplings for hubless pipe and fittings shall consist of an  P3003.9.1 Mechanical joints. Mechanical joints on drain-
           elastomeric sealing sleeve and a metallic shield that com-  age pipe shall be made with an elastomeric seal conforming
           ply with CISPI 310, ASTM C1277 or ASTM C1540. The     to ASTM C1173, ASTM D3212 or CSA B602. Mechanical
           elastomeric sealing sleeve shall conform to ASTM C564  joints shall not be installed in above-ground systems, unless
           or  CSA  B602  and  shall  have  a  center  stop.  Mechanical  otherwise approved. Joints shall be installed in accordance
           joint couplings  shall be installed in accordance with  the  with the manufacturer’s instructions.
           manufacturer’s instructions.
                                                                 P3003.9.2  Solvent  cementing.  Joint  surfaces  shall  be
         P3003.5 Concrete joints. Joints between concrete pipe and  clean and free from moisture. A purple primer, or other
         fittings shall be made with an elastomeric seal conforming to  approved primer, that conforms to ASTM F656 shall be
         ASTM C443, ASTM C1173, CSA A257.3 or CSA B602.          applied. Solvent cement not purple in color and conform-
         P3003.6 Copper and copper-alloy pipe and tubing. Joints  ing to ASTM D2564, CSA B137.3 or CSA B181.2 shall
         between copper or copper-alloy pipe tubing or fittings shall  be applied  to  all joint surfaces. The joint shall be  made
         comply with Sections P3003.6.1 through P3003.6.4.       while the cement is wet, and shall be in accordance with
                                                                 ASTM  D2855.  Solvent-cement  joints  shall  be  installed
           P3003.6.1  Brazed  joints.  All  joint  surfaces  shall  be  above or below ground.
           cleaned.  An  approved  flux  shall  be  applied  where
           required. Brazing materials shall have a melting point in  Exception: A primer shall not be required where all of
           excess of 1,000ºF (538ºC). Brazing alloys filler metal shall  the following conditions apply:
           be in accordance with AWS A5.8.                           1. The solvent cement used is third-party certified
           P3003.6.2 Mechanical joints. Mechanical joints shall be      as conforming to ASTM D2564.
           installed  in  accordance  with  the  manufacturer’s  instruc-  2. The solvent cement is used only for joining PVC
           tions.                                                       drain,  waste  and  vent  pipe  and  fittings  in  non-
           P3003.6.3 Soldered joints. Copper and copper-alloy joints    pressure applications in sizes up to and including
           shall  be  soldered  in  accordance  with  ASTM  B828.  Cut  4 inches (102 mm) in diameter



         666                                                                 2018 INTERNATIONAL RESIDENTIAL CODE  ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   686   687   688   689   690   691   692   693   694   695   696