SANITARY DRAINAGE



              P3007.3.3.1 Materials. Pipe and fitting materials shall          SECTION P3008
              be constructed of copper alloy, copper, CPVC, ductile         BACKWATER VALVES
              iron, PE, or PVC.                               P3008.1  Where  required.  Where  the  flood  level  rims  of
              P3007.3.3.2  Ratings.  Pipe  and  fittings  shall  be  rated  plumbing  fixtures  are  below  the  elevation  of  the  manhole
              for the maximum system operating pressure and tem-  cover of the next upstream manhole in the public sewer, the
              perature.   Pipe  fitting  materials  shall  be  compatible  fixtures shall be protected by a backwater valve installed in
              with the pipe material. Where pipe and fittings are bur-  the building drain, branch of the building drain or horizontal
              ied in the earth, they shall be suitable for burial.   branch serving such fixtures.
           P3007.3.4  Maximum  effluent  level.  The  effluent  level  P3008.2 Allowable installations.  Where plumbing  fixtures
           control  shall  be  adjusted  and  maintained  to  at  all  times  are installed on a floor with a finished floor elevation above
           prevent the effluent in the sump from rising to within 2  the elevation of the manhole cover of the next upstream man-
           inches (51 mm) of the invert of the gravity drain inlet into  hole in the public sewer, and a backwater valve is installed in
           the sump.                                          the building drain or horizontal branch serving such fixtures,
           P3007.3.5  Ejector  connection  to the  drainage  system.  the backwater valve shall be of the normally open type.
           Pumps connected to the drainage system shall connect to a  Exception: Normally closed backwater valve installations
           building sewer, building drain, soil stack, waste stack or  for existing buildings shall not be prohibited.
           horizontal branch drain. Where the discharge line connects  P3008.3  Material.  Backwater  valves  shall  comply  with
           into  horizontal  drainage  piping,  the  connection  shall  be  ASME A112.14.1, CSA B181.1 or CSA B181.2.
           made through  a wye  fitting  into the top of the  drainage
           piping and such wye fitting shall be located not less than  P3008.4  Location.  Backwater  valves  shall  be  installed  so
           10 pipe diameters from the base of any soil stack, waste  that access is provided to the working parts.
           stack or fixture drain.
         P3007.4  Sewage  pumps  and  sewage  ejectors.  A  sewage             SECTION P3009
         pump  or  sewage  ejector  shall  automatically  discharge  the  SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
         contents of the sump to the building drainage system.
                                                              P3009.1 Scope. The provisions of this section shall govern
         P3007.5 Macerating toilet systems and pumped waste sys-  the materials, design, construction and installation of subsur-
         tems. Macerating toilet systems and pumped waste systems  face  landscape  irrigation  systems  connected  to  nonpotable
         shall comply with ASME A112.3.4/CSA B45.9 and shall be  water from on-site water reuse systems.
         installed in accordance with the manufacturer’s instructions.
                                                              P3009.2 Materials. Above-ground drain, waste and vent pip-
         P3007.6 Capacity. Sewage pumps and sewage ejectors shall  ing for subsurface landscape irrigation systems shall conform
         have the capacity and head for the application requirements.  to one of the standards indicated in Table P3002.1(1). Sub-
         Pumps and ejectors that receive the discharge of water closets  surface landscape irrigation, underground building drainage
         shall be capable of handling spherical solids with a diameter  and vent pipe shall conform to one of the standards indicated
         of  up  to and  including  2  inches (51  mm). Other  pumps  or  in Table P3002.1(2).
         ejectors shall be capable of handling spherical solids with a
         diameter of up to and including  /  inch (13 mm). The mini-  P3009.3 Tests. Drain, waste and vent piping for subsurface
                                   1
                                     2
         mum capacity of a pump or ejector based on the diameter of  landscape  irrigation  systems  shall  be  tested  in  accordance
         the discharge pipe shall be in accordance with Table 3007.6.  with Section P2503.
                                                              P3009.4  Inspections.  Subsurface  landscape  irrigation  sys-
           Exceptions:
                                                              tems shall be inspected in accordance with Section R109.
              1. Grinder  pumps or  grinder ejectors  that receive  the
                discharge  of  water  closets  shall  have  a  discharge  P3009.5 Disinfection. Disinfection shall not be required for
                                     1
                opening of not less than 1 /  inches (32 mm).  on-site nonpotable reuse water for subsurface landscape irri-
                                                              gation systems.
                                      4
              2. Macerating toilet assemblies that serve single water
                closets  shall  have  a  discharge  opening  of  not  less  P3009.6 Coloring. On-site nonpotable reuse water used for
                    3
                than  /  inch (19 mm).                        subsurface landscape irrigation systems shall not be required
                     4
                                                              to be dyed.
                            TABLE 3007.6
         MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECTOR    P3009.7 Sizing. The system shall be sized in accordance with
               DIAMETER OF THE    CAPACITY OF PUMP OR EJECTOR  the sum of the output of all water sources connected to the
               DISCHARGE PIPE               (gpm)             subsurface  irrigation  system.  Where  gray-water  collection
                   (inches)                                   piping  is  connected  to  subsurface  landscape  irrigation  sys-
                     2                       2  1             tems, gray-water output shall be calculated according to the
                    2 / 2                    30               gallons-per-day-per-occupant  (liters  per  day  per  occupant)
                     1
                     3                       4  6             number based on the type of fixtures connected. The gray-
         For SI: 1 inch = 25.4 mm, 1 gallon per minute = 3.785 L/m.