BUILDING PLANNING



               R302.5.3  Other  penetrations.  Penetrations  through  the  The interior finish shall comply with the following:
               separation required in Section R302.6 shall be protected as  1. During  the  40  kW  exposure,  flames  shall  not
               required by Section R302.11, Item 4.                         spread to the ceiling.
             R302.6 Dwelling-garage fire separation. The garage shall    2. The flame shall not spread to the outer extremity
             be  separated  as  required  by  Table  R302.6.  Openings  in  of the sample on any wall or ceiling.
             garage walls shall comply with Section R302.5. Attachment
             of gypsum board shall comply with Table R702.3.5. The wall  3. Flashover,  as  defined  in  NFPA  286,  shall  not
             separation  provisions  of  Table  R302.6  shall  not  apply  to  occur.
             garage walls that are perpendicular to the adjacent dwelling  4. The  peak  heat  release  rate  throughout  the  test
             unit wall.                                                     shall not exceed 800 kW.
             R302.7 Under-stair protection. Enclosed space under stairs  5. The total smoke released throughout the test shall
             that is accessed by a door or access panel shall have walls,   not exceed 1,000 m .
                                                                                           2
             under-stair surface and any soffits protected on the enclosed  R302.10 Flame spread index and smoke-developed index
                     1
             side with  / -inch (12.7 mm) gypsum board.           for insulation. Flame spread and smoke-developed index for
                      2
             R302.8 Foam plastics. For requirements for foam plastics,  insulation  shall  be  in  accordance  with  Sections  R302.10.1
             see Section R316.                                    through R302.10.5.
             R302.9  Flame  spread  index  and  smoke-developed  index  R302.10.1  Insulation.  Insulating  materials  installed
             for  wall  and  ceiling  finishes.  Flame  spread  and  smoke-  within  floor-ceiling  assemblies,  roof-ceiling  assemblies,
             developed  indices  for  wall  and  ceiling  finishes  shall  be  in  wall assemblies, crawl spaces and attics shall comply with
             accordance with Sections R302.9.1 through R302.9.4.     the requirements of this section. They shall exhibit a flame
               R302.9.1 Flame spread index. Wall and ceiling finishes  spread  index  not  to  exceed  25  and  a  smoke-developed
               shall have a flame spread index of not greater than 200.  index not to exceed 450 where tested in accordance with
                                                                     ASTM E84 or UL 723. Insulating materials, where tested
                  Exception:  Flame  spread  index  requirements  for  fin-  in accordance with the requirements of this section, shall
                  ishes shall not apply to trim  defined as picture molds,  include facings, where used, such as vapor retarders, vapor
                  chair rails, baseboards and handrails; to doors and win-  permeable membranes and similar coverings.
                  dows or their frames; or to materials that are less than  / 28
                                                            1
                  inch (0.91 mm) in thickness cemented to the surface of  Exceptions:
                  walls or ceilings if these materials exhibit flame spread  1. Where such materials are installed in concealed
                  index values not greater than those of paper of this thick-  spaces, the flame spread index and smoke-devel-
                  ness cemented to a noncombustible backing.                oped  index  limitations  do  not  apply  to  the  fac-
               R302.9.2 Smoke-developed index. Wall and ceiling fin-        ings,  provided  that  the  facing  is  installed  in
               ishes shall have a smoke-developed index of not greater      substantial contact with the unexposed surface of
               than 450.                                                    the ceiling, floor or wall finish.
               R302.9.3 Testing. Tests shall be made in accordance with  2. Cellulose  fiber  loose-fill  insulation  that  is  not
               ASTM E84 or UL 723.                                          spray applied and that complies with the require-
                                                                            ments of Section R302.10.3 shall not be required
               R302.9.4 Alternative test  method.  As  an alternative  to   to meet the flame spread index requirements but
               having a flame spread index of not greater than 200 and a    shall  be  required  to  meet  a  smoke-developed
               smoke-developed  index  of  not  greater  than  450  where   index of not more than 450 where tested in accor-
               tested in accordance with ASTM E84 or UL 723, wall and       dance with CAN/ULC S102.2.
               ceiling finishes shall be permitted to be tested  in accor-
               dance with NFPA 286. Materials tested in accordance with  3. Foam  plastic  insulation  shall  comply  with  Sec-
               NFPA 286 shall meet the following criteria:                  tion R316.



                                                           TABLE R302.6
                                                   DWELLING-GARAGE SEPARATION
                                  SEPARATION                                          MATERIAL
                                                                          1
                                                                Not less than  / -inch gypsum board or equivalent applied to the
             From the residence and attics                                 2
                                                                garage side
                                                                          5
             From habitable rooms above the garage              Not less than  / -inch Type X gypsum board or equivalent
                                                                           8
             Structure(s) supporting floor/ceiling assemblies used for separation   Not less than  / -inch gypsum board or equivalent
                                                                          1
             required by this section                                      2
                                                                          1
                                                                Not less than  / -inch gypsum board or equivalent applied to the inte-
             Garages located less than 3 feet from a dwelling unit on the same lot   2
                                                                rior side of exterior walls that are within this area
             For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.