BUILDING PLANNING



             R302.13 Fire protection of floors. Floor assemblies that are  ing occupants. The openable area to the outdoors shall be not
             not required elsewhere in this code to be fire-resistance rated,  less than 4 percent of the floor area being ventilated.
                                   1
             shall  be  provided  with  a  / -inch  (12.7  mm)  gypsum  wall-  Exceptions:
                                    2
                             5
             board  membrane,  / -inch  (16  mm)  wood  structural  panel
                              8
             membrane, or equivalent on the underside of the floor fram-  1. The  glazed  areas  need  not  be  openable  where  the
             ing member. Penetrations or openings for ducts, vents, elec-  opening  is  not  required  by  Section  R310  and  a
             trical  outlets,  lighting,  devices,  luminaires,  wires,  speakers,  whole-house  mechanical  ventilation  system  is
             drainage, piping and similar openings or penetrations shall be  installed in accordance with Section M1505.
             permitted.
                                                                       2. The  glazed  areas  need  not  be  installed  in  rooms
               Exceptions:                                               where Exception 1 is satisfied and artificial light is
                                                                         provided  that  is  capable  of  producing  an  average
                  1. Floor assemblies located directly over a space pro-  illumination of 6 footcandles (65 lux) over the area
                    tected  by  an  automatic  sprinkler  system  in  accor-  of the room at a height of 30 inches (762 mm) above
                    dance  with  Section  P2904,  NFPA  13D,  or  other  the floor level.
                    approved equivalent sprinkler system.
                                                                       3. Use of sunroom and patio covers, as defined in Sec-
                  2. Floor assemblies located directly over a crawl space  tion R202, shall be permitted for natural ventilation if
                    not  intended  for  storage  or  for  the  installation  of  in excess of 40 percent of the exterior sunroom walls
                    fuel-fired or electric-powered heating appliances.
                                                                         are open, or are enclosed only by insect screening.
                  3. Portions of floor assemblies shall be permitted to be  R303.2  Adjoining  rooms.  For  the  purpose  of  determining
                    unprotected where complying with the following:  light and ventilation requirements, rooms shall be considered
                       3.1. The aggregate area of the unprotected por-  to be a portion of an adjoining room where not less than one-
                          tions does not exceed 80 square feet (7.4 m )  half of the area of the common wall is open and unobstructed
                                                             2
                          per story.                              and  provides  an  opening  of  not  less  than  one-tenth  of  the
                                                                  floor area of the interior room and not less than 25 square feet
                       3.2. Fireblocking  in  accordance  with  Section  (2.3 m ).
                                                                       2
                          R302.11.1 is installed along the perimeter of
                          the  unprotected  portion  to  separate  the  Exception: Openings required for light or ventilation shall
                          unprotected  portion  from  the  remainder  of  be permitted to open into a sunroom with thermal isolation
                          the floor assembly.                        or a patio cover, provided that there is an openable area
                                                                     between  the  adjoining  room  and  the  sunroom  or  patio
                  4. Wood floor assemblies using dimension lumber or
                    structural composite lumber equal to or greater than  cover of not less than one-tenth of the  floor area of the
                                                                                                              2
                    2-inch by 10-inch (50.8 mm by 254 mm) nominal    interior room and not less than 20 square feet (2 m ). The
                    dimension,  or  other  approved  floor  assemblies  minimum openable area to the outdoors shall be based on
                    demonstrating equivalent fire performance.       the total floor area being ventilated.
                                                                  R303.3 Bathrooms. Bathrooms, water closet compartments
             R302.14  Combustible  insulation  clearance.  Combustible
             insulation shall be separated not less than 3 inches (76 mm)  and other similar rooms shall be provided with aggregate glaz-
                                                                                                              2
             from recessed luminaires, fan motors and other heat-produc-  ing area in windows of not less than 3 square feet (0.3 m ), one-
             ing devices.                                         half of which shall be openable.
                                                                     Exception: The glazed areas shall not be required where
               Exception:  Where  heat-producing  devices  are  listed  for
               lesser clearances, combustible insulation complying with  artificial  light  and  a  local  exhaust  system  are  provided.
               3the listing requirements shall be separated in accordance  The minimum local exhaust rates shall be determined in
               with the conditions stipulated in the listing.        accordance  with  Section  M1505.   Exhaust  air  from  the
                                                                     space shall be exhausted directly to the outdoors.
               Recessed  luminaires  installed  in  the  building thermal  R303.4  Mechanical  ventilation.  Where  the  air  infiltration
             envelope shall meet the requirements of Section N1102.4.5 of  rate of a dwelling unit is 5 air changes per hour or less where
             this code.
                                                                  tested with a blower door at a pressure of 0.2 inch w.c (50 Pa)
                                                                  in  accordance  with  Section  N1102.4.1.2,  the  dwelling unit
                                                                  shall be provided with whole-house mechanical ventilation in
                              SECTION R303                        accordance with Section M1505.4.
                    LIGHT, VENTILATION AND HEATING
                                                                  R303.5 Opening location. Outdoor intake and exhaust open-
             R303.1  Habitable  rooms.  Habitable  rooms  shall  have  an  ings shall be located in accordance with Sections R303.5.1
             aggregate glazing area of not less than 8 percent of the floor  and R303.5.2.
             area of such rooms. Natural ventilation shall be through win-
             dows, skylights, doors, louvers or other approved openings to  R303.5.1 Intake openings. Mechanical and gravity out-
             the outdoor air. Such openings shall be provided with ready  door air intake openings shall be located not less than 10
             access or shall otherwise be readily controllable by the build-  feet (3048 mm) from any hazardous or noxious contami-