                                                         TABLE R308.3.1(1)
                                  MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
                                                                                          GLAZING IN
                                  GLAZING IN
                                                                                          DOORS AND
               EXPOSED SURFACE    STORM OR      GLAZING IN   GLAZED PANELS   GLAZED PANELS   ENCLOSURES   SLIDING GLASS
                                                                           REGULATED BY
                                                            REGULATED BY
               AREA OF ONE SIDE   COMBINATION    DOORS      SECTION R308.4.3  SECTION R308.4.2  REGULATED BY  DOORS PATIO TYPE
                  OF ONE LITE      DOORS      (Category Class)  (Category Class)  (Category Class)  SECTION 308.4.5  (Category Class)
                                (Category Class)
                                                                                         (Category Class)
             9 square feet or less    I            I             NR             I             II            II
             More than 9 square feet   II          II            II             II            II            II
             For SI: 1 square foot = 0.0929 m . 2
             NR = No Requirement.
                                                         TABLE R308.3.1(2)
                                     MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
                                   GLAZED PANELS REGULATED BY   GLAZED PANELS REGULATED BY   DOORS AND ENCLOSURES REGULATED
              EXPOSED SURFACE AREA       SECTION R308.4.3           SECTION R308.4.2          BY SECTION R308.4.5 a
              OF ONE SIDE OF ONE LITE
                                         (Category Class)           (Category Class)            (Category Class)
             9 square feet or less       No requirement                  B                           A
             More than 9 square feet          A                          A                           A
             For SI: 1 square foot = 0.0929 m . 2
             a. Use is permitted only by the exception to Section R308.3.1.


                       Glazing  in  this  application  shall  comply  with       degrees  (0.79  rad)  of  horizontal]  surface
                       Section R308.4.3.                                         adjacent to the glass exterior.
                    4. Glazing that is adjacent to the fixed panel of patio  R308.4.4  Glazing  in  guards  and  railings. Glazing  in
                       doors.                                        guards  and  railings,  including  structural  baluster  panels
               R308.4.3 Glazing in windows.  Glazing in an individual  and  nonstructural  in-fill  panels,  regardless  of  area  or
               fixed or operable panel that meets all of the following con-  height above a walking surface shall be considered to be a
               ditions shall be considered to be a hazardous location:  hazardous location.
                  1. The exposed area of an individual pane is larger than  R308.4.4.1 Structural glass baluster panels. Guards
                    9 square feet (0.836 m ).                          with structural glass baluster panels shall be installed
                                      2
                                                                       with  an  attached  top  rail  or  handrail.  The  top  rail  or
                  2. The bottom edge of the glazing is less than 18 inches  handrail shall be supported by not less than three glass
                    (457 mm) above the floor.                          baluster  panels,  or  shall  be  otherwise  supported  to
                  3. The top edge of the glazing is more than 36 inches  remain in place should one glass baluster panel fail.
                    (914 mm) above the floor.                            Exception:  An attached top  rail or handrail is not
                  4. One or more walking surfaces are within 36 inches   required  where  the  glass  baluster  panels  are  lami-
                    (914 mm), measured horizontally and in a straight    nated  glass  with  two  or  more  glass  plies  of  equal
                    line, of the glazing.                                thickness and of the same glass type.
                       Exceptions:                                   R308.4.5  Glazing  and  wet  surfaces.  Glazing  in  walls,
                         1. Decorative glazing.                      enclosures  or  fences  containing  or  facing  hot  tubs,  spas,
                                                                     whirlpools,  saunas,  steam  rooms,  bathtubs,  showers  and
                         2. Where glazing is adjacent to a walking sur-  indoor  or  outdoor  swimming  pools  where  the  bottom
                           face and a horizontal rail is installed 34 to  exposed edge of the glazing is less than 60 inches (1524
                           38 inches (864 to 965 mm) above the walk-  mm)  measured  vertically  above  any  standing  or  walking
                           ing  surface.  The  rail  shall  be  capable  of  surface shall be considered to be a hazardous location.  This
                           withstanding  a  horizontal  load  of  50  shall apply to single glazing and each pane in multiple glaz-
                           pounds per linear foot (730 N/m) without  ing.
                           contacting the glass and have a cross-sec-
                                                    1
                           tional height of not less than 1 /  inches (38  Exception:  Glazing that is more than 60 inches (1524
                                                     2
                           mm).                                        mm), measured horizontally and in a straight line, from
                         3. Outboard  panes  in  insulating  glass  units  the water’s edge of a bathtub, hot tub, spa, whirlpool or
                                                                       swimming pool or from the edge of a shower, sauna or
                           and other multiple glazed panels where the  steam room.
                           bottom edge of the glass is 25 feet (7620
                           mm) or more above grade, a roof, walking  R308.4.6 Glazing adjacent to stairs and ramps.  Glaz-
                           surfaces  or  other  horizontal  [within  45  ing where the bottom exposed edge of the glazing is less
                                                                     than 36 inches (914 mm) above the plane of the adjacent


             2018 INTERNATIONAL RESIDENTIAL CODE ®                                                                67
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   87   88   89   90   91   92   93   94   95   96   97