Page 165 - Modernfold Architectural Products
P. 165

Acousti-Seal  ENCORE  Automated Technical Data
                               ®
                                           ®
               10 22 26 (10650) Operable Partitions



               ACOUSTI-SEAL  ENCORE  AUTOMATED SERIES TECHNICAL DATA
                                    ®
                                                  ®
               PART 3 – EXECUTION                              3.3 ADJUSTING
                                                               A.  Adjust operable partitions to operate smoothly,
               3.1 INSTALLATION                                   easily, and quietly, free from binding, warp,
               A.  General: Comply with ASTM E557, operable       excessive deflection, distortion, nonalignment,
                  partition manufacturer’s written installation   misplacement, disruption, or malfunction,
                  instructions, Drawings and approved Shop        throughout entire operational range. Lubricate
                  Drawings.                                       hardware and other moving parts.
               B.  Install operable partitions and accessories after
                 other finishing operations, including painting have   3.4 EXAMINATION
                 been completed.                               A.  Examine flooring, structural support, and opening,
               C.  Match operable partitions by installing panels   with Installer present, for compliance with
                  from marked packages in numbered sequence       requirements for installation tolerances and other
                  indicated on Shop Drawings.                     conditions affecting performance of operable
               D.  Broken, cracked, chipped, deformed or          partitions. Proceed with installation only after
                  unmatched panels are not acceptable.            unsatisfactory conditions have been corrected.

               3.2 CLEANING AND PROTECTION                     3.5 DEMONSTRATION
               A.  Clean partition surfaces upon completing    A.  Demonstrate proper operation and maintenance
                  installation of operable partitions to remove   procedures to Owner’s representative.
                  dust, dirt, adhesives, and other foreign materials   B.  Provide Operation and Maintenance Manual to
                  according to manufacturer’s written instructions.  Owner’s representative.
               B.  Provide final protection and maintain conditions
                 in a manner acceptable to the manufacturer and
                 Installer that insure operable partitions are without
                 damage or deterioration at time of Substantial
                 Completion.









                                                                Welded Steel Skin Max Height
                Acousti-Seal                         without Pass Door                 with Pass Door
                            ®
                Encore  Automated             52  STC    54 STC     56 STC     52  STC    54 STC     56 STC
                       ®
                                                         20’-4”
                                                                               19’-4”
                                                                     16’-4”
                                              24’-4”
                                                                                                     13’-4”
                                                                                          17’-4”
                #14  Bracket Mounted Track  (7417 mm)  (6198 mm)   (4978 mm)  (5893 mm) (5283 mm)  (4064 mm)
                                                                                          12’-4”
                                              12’-4”
                                                                                                     12’-4”
                                                                               12’-4”
                                                                     12’-4”
                                                         12’-4”
                #30   Bracket Mounted Track  (3759 mm)  (3759 mm)  (3759 mm)  (3759 mm) (3759 mm)  (3759 mm)